Purpose: To assess the reproducibility of percentage ventilated lung volume (%VV) measurements in healthy volunteers acquired by fluorine ( F)-MRI of inhaled perfluoropropane, implemented at two research sites.

Methods: In this prospective, ethically approved study, 40 healthy participants were recruited (May 2018-June 2019) to one of two research sites. Participants underwent a single MRI scan session on a 3T scanner, involving periodic inhalation of a 79% perfluoropropane/21% oxygen gas mixture. Each gas inhalation session lasted about 30 seconds, consisting of three deep breaths of gas followed by a breath-hold. Four F-MR ventilation images were acquired per participant, each separated by approximately 6 minutes. The value of %VV was determined by registering separately acquired H images to ventilation images before semi-automated image segmentation, performed independently by two observers. Reproducibility of %VV measurements was assessed by components of variance, intraclass correlation coefficients, coefficients of variation (CoV), and the Dice similarity coefficient.

Results: The MRI scans were well tolerated throughout, with no adverse events. There was a high degree of consistency in %VV measurements for each participant (CoV = 0.43%; CoV = 0.63%), with overall precision of %VV measurements determined to be within ± 1.7% (95% confidence interval). Interobserver agreement in %VV measurements revealed a high mean Dice similarity coefficient (SD) of 0.97 (0.02), with only minor discrepancies between observers.

Conclusion: We demonstrate good reproducibility of %VV measurements in a group of healthy participants using F-MRI of inhaled perfluoropropane. Our methods have been successfully implemented across two different study sites, supporting the feasibility of performing larger multicenter clinical studies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7986730PMC
http://dx.doi.org/10.1002/mrm.28660DOI Listing

Publication Analysis

Top Keywords

%vv measurements
24
f-mr ventilation
8
healthy volunteers
8
f-mri inhaled
8
inhaled perfluoropropane
8
healthy participants
8
ventilation images
8
reproducibility %vv
8
dice similarity
8
%vv
7

Similar Publications

Anions play a crucial role in various environmental, chemical, and biological processes. Among various anions, the production of perchlorate (ClO ) ion is expected to rise in upcoming years, and thus, an efficient method for the detection of perchlorate ion is highly desirable. In this effort, a pyridyl-benzimidazole-based luminescent probe (RSB1) containing two N-H donor sites has been synthesized for selective detection of perchlorate ion.

View Article and Find Full Text PDF

Background: Iron deficiency (ID) is currently defined as a serum ferritin level <100 or 100 to 299 ng/mL with transferrin saturation (TSAT) <20%. Serum ferritin and TSAT are currently used to define absolute and functional ID. However, individual markers of iron metabolism may be more informative than current arbitrary definitions of ID.

View Article and Find Full Text PDF

To improve the stability of D-limonene, a protective barrier is essential to prevent degradation and maintain its integrity. Therefore, the potential of using seed gum (LPSG) as a novel source for creating electrospun nanofibers for D-limonene encapsulation was investigated by varying LPSG concentrations (0.25%, 0.

View Article and Find Full Text PDF

Writing and drawing tilts after right hemisphere stroke are signs of a wrong verticality representation.

Ann Phys Rehabil Med

January 2025

University Grenoble Alpes, UMR CNRS 5105 Neuropsychology and NeuroCognition, CHU Grenoble Alpes, Dept of NeuroRehabilitation South Hospital, Cs 10217-38043 Grenoble cedex 9, France. Electronic address:

Background: Many signs of spatial dysgraphia and drawing errors after right hemispheric stroke (RHS) have been attributed to spatial neglect or impaired sensory feedback. Counterclockwise (contralesional) tilts of graphomotor productions remained to be explained.

Objective: To test whether graphomotor tilts stem from a tilted representation of verticality transposed to the top/bottom axis of the sheet of paper, using data from the DOBRAS cohort.

View Article and Find Full Text PDF

In this research, we report a simple fluorescent probe designed to detect thallium(iii) ions (Tl) in artificial urine samples. The Tl signaling probe (TP-1) was readily prepared from 2-acetyl-6-methoxynaphthalene and hydrazine. In a pH 4.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!