Targeted tibio-peroneal re-entry during subintimal revascularization using the Outback® catheter.

CVIR Endovasc

Department of Diagnostic and Interventional Radiology, University hospital Augsburg, Stenglinstr. 2, 86156, Augsburg, Germany.

Published: January 2021

Background: Re-entry devices are used regularly in subintimal recanalization of chronic occlusions of the iliac and femoro-popliteal arteries and significantly contribute to the high success rate of these interventions. However, the use in tibio-peroneal arteries has only been described in few cases so far. The present work is a retrospective evaluation of the Outback® re-entry device for gaining targeted true lumen access at the level of the tibio-peroneal arteries.

Methods: From 9/2017 until 10/2020 the Outback® catheter was used in case of failed spontaneous re-entry at the level of the tibio-peroneal arteries in 14 patients either instead of the usual retrograde approach via a pedal/distal-crural access (n = 11) or in combination with it (n = 3). Baseline demographic and clinical data, morphologic characteristics of the occlusions, procedural succedss, as well as the Society of Vascular Surgery (SVS) runoff score before and after revascularization were documented.

Results: All patients (median age: 78 years; range: 66-93) suffered from peripheral artery occlusive disease Rutherford stage 4 to 6 with a median lesion length of 12 cm (range: 7-35). Technical and procedural success was achieved in all 14 patients. The mean re-entry accuracy was 0.25 cm (range: 0-0.8). The SVS runoff score improved from a median of 14.5 (interquartile range IQR: 10.8-16.4) to 7 (IQR: 6.3-7) (p < 0.01).

Conclusions: The use of the Outback® catheter for targeted tibio-peroneal re-entry is associated with a high technical and procedural success rate and should be considered in case of otherwise failed ante- and retrograde recanalization.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7843800PMC
http://dx.doi.org/10.1186/s42155-021-00206-wDOI Listing

Publication Analysis

Top Keywords

outback® catheter
8
tibio-peroneal arteries
8
level tibio-peroneal
8
svs runoff
8
runoff score
8
re-entry
5
targeted tibio-peroneal
4
tibio-peroneal re-entry
4
re-entry subintimal
4
subintimal revascularization
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?