A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Percardiac closure of large apical ventricular septal defects in infants: Novel modifications and mid-term results. | LitMetric

Background/aim: Both open heart surgery and percutaneous approaches retain several limitations in closing large apical muscular ventricular septal defects (AmVSD) in infants. We present probe-assisted percardiac device closure (PDC), an exclusively transoesophageal-echocardiography guided technique, as an alternative with midterm results.

Methods: Thirty-six infants with large AmVSDs (single or multiple-holed) underwent PDC in our department. Mean AmVSD for single and multiple-holed measured 7.2 ± 2.4 mm and 6.3 ± 3.4 mm, respectively. Subjects presented with a spectrum of cardiopulmonary sequelae and growth retardation, either alone or combined. Some were ventilator dependent and re-do cases. In addition, AmVSDs were categorized: cylindrical, tunnel and cave-like shaped as per color Doppler interrogation. Pursuant to cardiac access and deployment technique, subjects were apportioned: group A; inferior median sternotomy (perventricular), B; right mini-thoracotomy (peratrial) and C; complete median sternotomy (perventricular). Under exclusive echocardiography, the Z- or J probe-assisted delivery system was utilized to access AmVSDs and implant device(s) via aforementioned techniques.

Results: Forty-two muscular ventricular septal devices (8.4 ± 2.6 mm) were implanted in 36 subjects uneventfully. Seventeen "complex," and 10 cylindrical or straight tunnel-shapedAmVSDs (including 2 re-do patients) suited perventricular and peratrial techniques respectively. Comparatively, group B exhibited shorter procedural indices than A (p < .01). Five of 15 multiple-holed AmVSDs (four Swiss cheese) required two or three devices for a satisfactory occlusion. Nevertheless, post occlusion insignificant residual shunts( ≤ 2 mm) seldom achieved spontaneous closure, and at 36-month follow-up complete closure was 67%. Residual shunt persisted amongst multiple-holed. All patients improved during follow up.

Conclusion: PDC is feasible, safe and effective alternative technique for AmVSD in infants.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7898510PMC
http://dx.doi.org/10.1111/jocs.15291DOI Listing

Publication Analysis

Top Keywords

ventricular septal
12
large apical
8
septal defects
8
muscular ventricular
8
single multiple-holed
8
median sternotomy
8
sternotomy perventricular
8
percardiac closure
4
closure large
4
apical ventricular
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!