A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@remsenmedia.com&api_key=81853a771c3a3a2c6b2553a65bc33b056f08&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A colorimetric indicator-displacement assay based on stable Cu selective carbon dots for fluorescence turn-on detection of pyrophosphate anions in urine. | LitMetric

Determination of PPi levels in urine represents a measurable factor for diagnostic, treatment, and monitoring of urolithiasis. Owing to the quenching ability of Cu on fluorescent carbon dots (CDs) and strong binding affinity between Cu and PPi, we develop a new off-on assay for PPi detection using newly BPHA CDs (BPHA: N,N-bis(pyridin-2-ylmethyl)hexan-1-amine). The fluorescence intensity of BPHA CDs was significantly quenched by Cu ("off") through forming BPHA CDs/Cu complexes and the fluorescence intensity of BPHA CDs /Cu system was completely resumed by PPi ("on") owing to the release of free Cu. The fluorescence turn-off/on approach showed a highly selective response to PPi over the large family of other anions. The detection limits were 0.094 μM for Cu and 0.025 μM for PPi, respectively. A wide linear range for PPi was up to 4400 μM. The indicator displacement assay (IDAs) using pyrocatechol violet (PV) as a colorimetric indicator was carried out to detect PPi with the naked eyes. The "off-on" fluorescent sensor based on BPHA CDs shows many merits, including convenient operation, cost-saving, high sensitivity, selectivity, stability and wide detecting range, which is applied to PPi detection in human urine sample.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.saa.2021.119479DOI Listing

Publication Analysis

Top Keywords

bpha cds
16
ppi
9
carbon dots
8
ppi detection
8
fluorescence intensity
8
intensity bpha
8
bpha
6
cds
5
colorimetric indicator-displacement
4
indicator-displacement assay
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!