This work explores the feasibility of coupling two different techniques, the impedance and the transient plane source (TPS) principle, to quantify the moisture content and its compositional parameters simultaneously. The sensor is realized directly on textiles with the use of printing and coating technology. Impedance measurements use the fluid's electrical properties, while the TPS measurements are based on the thermal effusivity of the liquid. Impedance and TPS measurements show equal competency in measuring the fluid volume with a lowest measurable quantity of 0.5 μL, enabling ultralow volume passive measurements for sweat analysis. Both sensor principles were tested by monitoring the drying of a wet cloth and the measurements show perfect repeatability and accuracy. Nevertheless, when the biofluid property changes, the TPS sensor does not reflect this information on its readings, whereas, on the other hand, impedance can provide information on compositional changes. However, since the volume of the fluid changes simultaneously, one cannot differentiate between a volume change and a compositional change from impedance measurements alone. Therefore, we show in this work that we can apply impedance to measure the compositional properties; meanwhile, the TPS measurements accurately carry out volume measurements irrespective of the interferences from its compositional variations. To prove this, both of these techniques are applied for the quantification and composition monitoring of sweat, showing the capability to measure moisture content and compositional parameters simultaneously. TPS measurements can also be an indicator of the local temperature of the medium confined by the sensor, and it does not influence the fluid parameters. Compiling both impedance and thermal sensors in a single platform triggers smart wearable prospects of metering the liquid volume and simultaneously analyzing other compositional changes and body temperature. Finally, the repeatability and stability of the sensor readings and the washability of the device are tested. This device could be a potential sensing tool in real-life applications, such as wound monitoring and sweat analysis, and could be a promising addition toward future smart wearable sensors.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acssensors.0c02037DOI Listing

Publication Analysis

Top Keywords

tps measurements
16
measurements
9
impedance
8
impedance thermal
8
moisture content
8
content compositional
8
compositional parameters
8
parameters simultaneously
8
impedance measurements
8
properties tps
8

Similar Publications

Aim: To study the dosimetric behavior of dose computational algorithms in inhomogeneous medium using CMS XiO and MONACO treatment planning system (TPS) for 4 megavoltage (MV), 6 MV and 15 MV photon beam energies.

Material And Methods: Styrofoam blocks of thickness 1.90 cm, 3.

View Article and Find Full Text PDF

Background: Modern radiation therapy techniques, such as intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT), use complex fluence modulation strategies to achieve optimal patient dose distribution. Ensuring their accuracy necessitates rigorous patient-specific quality assurance (PSQA), traditionally done through pretreatment measurements with detector arrays. While effective, these methods are labor-intensive and time-consuming.

View Article and Find Full Text PDF

We present a versatile flow-through tube passive sampling device (TPS), with a controllable feedwater volumetric flow, that can be calibrated against the feedwater load of organic micropollutants (OMPs). This semipassive approach has the advantage of a determinable water load feeding the sampling device. The design of the TPS allows for new sampling scenarios in closed piping while providing stable and controlled sampling conditions.

View Article and Find Full Text PDF

Purpose: Transient arginine vasopressin deficiency (AVP-D), previously called diabetes insipidus, is a well-known complication of transsphenoidal pituitary surgery (TPS) with no definite predictive biomarker to date making it difficult to anticipate. While oxytocin (OXT) was previously suggested as a possible biomarker to predict syndrome of inappropriate diuresis (SIAD)-related hyponatraemia after TPS, its secretion in patients presenting with AVP-D remains poorly understood. We therefore hypothesized that OXT might present a different secretion in the case of AVP-D which would support its potential as an early biomarker of AVP-D.

View Article and Find Full Text PDF

. To investigate the effect of the position and orientation of the detector and its influence on the determination of output factors (OF) for small fields for a linear accelerator (MR-linac) integrated with 1.5 T magnetic resonance following the TRS-483 formalism.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!