Transverse and T-type acetabular fractures are high energy fractures that may be associated with a disruption of the pelvic ring. While several studies report upon clinical findings and outcomes associated with combination injuries of the pelvic ring and acetabulum, there are limited reports discussing surgical treatment strategies for reduction and stabilization. Herein we focus on describing reduction and stabilization techniques of transverse or transverse-variant acetabular fractures with an associated ipsilateral partial disruption of the sacroiliac joint.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.injury.2020.12.011DOI Listing

Publication Analysis

Top Keywords

acetabular fractures
12
reduction stabilization
12
transverse transverse-variant
8
transverse-variant acetabular
8
sacroiliac joint
8
fractures associated
8
pelvic ring
8
fractures
4
fractures ipsilateral
4
ipsilateral sacroiliac
4

Similar Publications

Dislocation is the second most common indication for revision total hip arthroplasty (THA). In revision cases the dislocation rate can be as high as 5-30%. The aim of this study was to assess the outcome, specifically the dislocation rate in revision THA where a dual mobility cup was used.

View Article and Find Full Text PDF

Background: Gravid females with pelvic fractures are rarely encountered by the orthopaedic trauma surgeon. The initial injury can be detrimental to the pregnant patient, but an unnecessary "second hit" from surgery could also contribute to the outcome of the fetus. Understanding the surgical risks for this unique patient population requires knowledge about the negative effects of anesthesia, surgical exposures, and radiation.

View Article and Find Full Text PDF

Determinants for successful medullary fixation of the superior ramus.

Injury

January 2025

Department of Orthopaedic Surgery, Cedars - Sinai Medical Center, Los Angeles, CA, USA. Electronic address:

Objectives: The purpose of this study is to determine what demographic and anatomical variables affect successful placement of a superior medullary ramus screw, and how they affect the maximal diameter of that screw.

Methods: Design: Prognostic Level IV SETTING: Level I Trauma Center Patients/Participants: Two hundred consecutive patients underwent computed tomography (CT) of the pelvis. We included those patients aged 18 and older without osseous injury or abnormalities precluding measurement.

View Article and Find Full Text PDF

Background: Pelvic ring and acetabular fractures are among the most complicated and severe injury patterns in orthopaedic trauma surgery. Inpatient treatment is not only costly but also very time-consuming. The aim of this study is to identify predictors leading to a prolonged length of hospital stay.

View Article and Find Full Text PDF

Large-diameter heads (LDHs) in total hip arthroplasty (THA) enhance range of motion but require thinner liners. Monoblock acetabular components with ceramic liners could reduce liner fracture risks during modular acetabular component assembly. This study aims to confirm the safety and clinical performance of the monoblock Maxera Cup in THA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!