In this paper, we report a novel teeter-totter type accelerometer based on glass-silicon composite wafers. Unlike the ordinary micro-electro-mechanical systems (MEMS) accelerometers, the entire structure of the accelerometer, includes the mass, the springs, and the composite wafer. The composite wafer is expected to serve as the electrical feedthrough and the fixed capacitance plate at the same time, to simplify the fabrication process, and to save on chip area. It is manufactured by filling melted borosilicate glass into an etched silicon wafer and polishing the wafer flat. A sensitivity of 51.622 mV/g in the range of ±5 g (g = 9.8 m/s2), a zero-bias stability under 0.2 mg, and the noise floor with 11.28 µg/√Hz were obtained, which meet the needs of most acceleration detecting applications. The micromachining solution is beneficial for vertical interconnection and miniaturization of MEMS devices.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7911678 | PMC |
http://dx.doi.org/10.3390/mi12020102 | DOI Listing |
BMJ Open
January 2025
College of Medicine and Dentistry, James Cook University, Queensland Research Centre for Peripheral Vascular Disease, Townsville, Queensland, Australia.
Introduction: Patients with peripheral artery disease (PAD) can experience intermittent claudication, which limits walking capacity and the ability to undertake daily activities. While exercise therapy is an established way to improve walking capacity in people with PAD, it is not feasible in all patients. Neuromuscular electrical stimulation (NMES) provides a way to passively induce repeated muscle contractions and has been widely used as a therapy for chronic conditions that limit functional capacity.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Laboratory of Vibration and Noise, Naval University of Engineering, Wuhan 430033, China.
Pulsation noise in the piping system generated by the excitation of the pump source seriously affects the reliability of the pipeline system and mechanical equipment. The active noise control can effectively suppress the low-frequency noise in the liquid-filled pipeline. Active control methods with intrusive secondary sources generally use dynamic pressure sensors or hydrophones to collect signals, which destroy the structure of the pipe.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Advanced Institute of Convergence Technology, 145 Gwanggyo-ro, Yeongtong-gu, Suwon-si 16229, Gyeonggi-do, Republic of Korea.
According to South Korea's Ministry of Employment and Labor, approximately 25,000 construction workers suffered from various injuries between 2015 and 2019. Additionally, about 500 fatalities occur annually, and multiple studies are being conducted to prevent these accidents and quickly identify their occurrence to secure the golden time for the injured. Recently, AI-based video analysis systems for detecting safety accidents have been introduced.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Yunnan Earthquake Agency, Kunming 650224, China.
The strong motion records collected in full-scale structures provide the ultimate evidence of how real structures, in situ, respond to earthquakes. This paper presents a novel method for visualization, in three dimensions (3D), of the collective motion by a dense array of sensors in a building. The method is based on one- and two-dimensional biharmonic spline interpolation of the motion recorded by multiple sensors on the same or multiple floors.
View Article and Find Full Text PDFSensors (Basel)
January 2025
School of Computer Science, University of Birmingham, Birmingham B15 2TT, UK.
Objective and continuous monitoring of Parkinson's disease (PD) tremor in free-living conditions could benefit both individual patient care and clinical trials, by overcoming the snapshot nature of clinical assessments. To enable robust detection of tremor in the context of limited amounts of labeled training data, we propose to use prototypical networks, which can embed domain expertise about the heterogeneous tremor and non-tremor sub-classes. We evaluated our approach using data from the Parkinson@Home Validation study, including 8 PD patients with tremor, 16 PD patients without tremor, and 24 age-matched controls.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!