Objective: To evaluate the effect of intravenous iodinated contrast on estimated glomerular filtration rate (eGFR) when administered immediately after thermal ablation of clinically localized T1a (cT1a) renal cell carcinoma (RCC).
Methods: This HIPAA-compliant, dual-center retrospective study was performed under a waiver of informed consent. Three hundred forty-two consecutive patients with cT1a biopsy-proven RCC were treated with percutaneous ablation between January 2010 and December 2017. Immediate post-ablation contrast-enhanced CT was the routine standard of care at one institution (contrast group), but not the other (control group). One-month pre- and 6-month post-ablation eGFR were compared using the Wilcoxon signed-rank test or the Kruskal-Wallis test. Multivariate linear regression was used to determine the effect of contrast on eGFR. A 1:1 propensity score matching was performed for all patients with a logistic model using patient, tumor, and procedural covariates.
Results: In total, 246 patients (158 M; median age 69 years, IQR 62-74) were included. Median tumor diameter (2.4 vs 2.5, p = 0.23) and RENAL nephrometry scores (6 vs 6, p = 0.92), surrogates for ablation zone size, were similar. Baseline kidney function was similar for the control and contrast groups, respectively (median eGFR: 70 vs 74 mL/min/1.73 m, p = 0.29). There was an expected mild decline in eGFR after ablation (control: 70 vs 60 mL/min/1.73 m, p < 0.001; contrast: 75 vs 71 mL/min/1.73 m, p = 0.001). Intravenous iodinated contrast was not associated with a decline in eGFR on multivariate linear regression (1.91, 95% CI - 3.43-7.24, p = 0.46) or 1:1 propensity score-matched model (- 0.33, 95% CI - 6.81-6.15, p = 0.92).
Conclusion: Intravenous iodinated contrast administered during ablation of cT1a RCC has no effect on eGFR.
Key Points: • Intravenous iodinated contrast administered during thermal ablation of clinically localized T1a renal cell carcinoma has no effect on kidney function. • Thermal ablation of clinically localized T1a renal cell carcinoma results in a mild decline in kidney function. • A decline in kidney function is similar for radiofrequency and microwave ablation of clinically localized T1a renal cell carcinoma.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00330-020-07613-y | DOI Listing |
Purpose: With the widespread introduction of dual energy computed tomography (DECT), applications utilizing the spectral information to perform material decomposition became available. Among these, a popular application is to decompose contrast-enhanced CT images into virtual non-contrast (VNC) or virtual non-iodine images and into iodine maps. In 2021, photon-counting CT (PCCT) was introduced, which is another spectral CT modality.
View Article and Find Full Text PDFEur Radiol
January 2025
Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Augsburg, Germany.
Objectives: The purpose of this study was to evaluate whether the iodine contrast in blood and solid organs differs between men and women and to evaluate the effect of BMI, height, weight, and blood volume (BV) on sex-specific contrast in staging CT.
Materials And Methods: Patients receiving a venous-phase thoracoabdominal Photon-Counting Detector CT (PCD-CT) scan with 100- or 120-mL CM between 08/2021 and 01/2022 were retrospectively included in this single-center study. Image analysis was performed by measuring iodine contrast in the liver, portal vein, spleen, left atrium, left ventricle, pulmonary trunk, ascending and descending aorta on spectral PCD-CT datasets.
Vet Ophthalmol
January 2025
Cardiology & Cardiac Surgery, Department of Clinical Sciences, College of Veterinary Medicine and Biomedical Sciences, Colorado State University, Fort Collins, Colorado, USA.
A 4-year-old female spayed mixed-breed dog received enucleation surgery of the right eye in 2018 following the diagnosis of glaucoma. The patient was presented in 2021 for recurrent swelling of the right orbit. Ultrasound confirmed the presence of a cystic structure, and chemical ablation with 1% polidocanol (compounded, Stokes Pharmacy, Mt.
View Article and Find Full Text PDFPurpose: As the pancreas is a low contrast visibility organ, pancreatic ductal adenocarcinoma detection is challenging due to subtle attenuation differences between tumor and pancreatic parenchyma. Photon counting CT (PCCT) has superior iodine contrast-to-noise ratio than conventional CT and also affords the creation of low keV virtual monoenergetic images, both of which increase adenocarcinoma conspicuity. The purpose therefore was to identify the optimal virtual monoenergy for visualizing PDAC during the pancreatic parenchymal phase of enhancement at PCCT using both quantitative and qualitative analyses.
View Article and Find Full Text PDFNeuroradiol J
January 2025
Department of Neurosurgery, Brain Research Institute, Niigata University, Niigata, Japan.
Gadolinium contrast medium can serve as an alternative to iodinated contrast medium when the latter is unsuitable. In this report, we describe a case of a carotid-ophthalmic aneurysm in which angiograms were obtained using gadolinium contrast medium for flow-diverter stent placement due to the patient's history of bronchial asthma and hypersensitivity reactions to iodinated contrast medium. To enhance the visibility of gadolinium contrast medium, which typically provides lower contrast compared to iodinated contrast medium, we employed a contrast-enhancing and noise-reducing protocol on our image-guided therapy system.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!