Capillary-driven microfluidic devices are of significant interest for on-site analysis because they do not require external pumps and can be made from inexpensive materials. Among capillary-driven devices, those made from paper and polyester film are among the most common and have been used in a wide array of applications. However, since capillary forces are the only driving force, flow is difficult to control, and passive flow control methods such as changing the geometry must be used to accomplish various analytical applications. This study presents several new flow control methods that can be utilized in a laminate capillary-driven microfluidic device to increase available functionality. First, we introduce push and burst valve systems that can stop and start flow. These valves can stop flow for >30 min and be opened by either pressing the channel or inflowing other fluids to the valve region. Next, we propose flow control methods for Y-shaped channels that enable more functions. In one example, we demonstrate the ability to accurately control concentration to create laminar, gradient, and fully mixed flows. In a second example, flow velocity in the main channel is controlled by adjusting the length of the inlet channel. In addition, the flow velocity is constant as the inlet length increases. Finally, the flow velocity in the Y-shaped device as a function of channel height and fluid properties such as viscosity and surface tension was examined. As in previous studies on capillary-driven channels, the flow rate was affected by each parameter. The fluidic control tools presented here will enable new designs and functions for low cost point of need assays across a variety of fields.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7990706PMC
http://dx.doi.org/10.1039/d0an02279aDOI Listing

Publication Analysis

Top Keywords

flow control
16
capillary-driven microfluidic
12
control methods
12
flow velocity
12
flow
11
laminate capillary-driven
8
microfluidic device
8
control
6
capillary-driven
5
control laminate
4

Similar Publications

Plasmids play a vital role in synthetic biology by enabling the introduction and expression of foreign genes in various organisms, thereby facilitating the construction of biological circuits and pathways within and between cell populations. For many applications, maintaining functional plasmids without antibiotic selection is critical. This study introduces an open-hardware-based microfluidic workflow for analyzing plasmid retention by culturing single cells in gel microdroplets and quantifying microcolonies using fluorescence microscopy.

View Article and Find Full Text PDF

pH regulation of eukaryotic cells is of crucial importance and influences different mechanisms including chemical kinetics, buffer effects, metabolic activity, membrane transport and cell shape parameters. In this study, we develop a microfluidic system to rapidly and precisely control a continuous flow of ionic chemical species to acutely challenge the intracellular pH regulation mechanisms and confront predictive models. We monitor the intracellular pH dynamics in real-time using pH-sensitive fluorescence imaging and establish a robust mathematical tool to translate the fluorescence signals to pH values.

View Article and Find Full Text PDF

Platelets are hyperactive in patients with type2 diabetes (T2DM), they adhere to vascular endothelium and play a key role in macrovascular complications. Platelets activity can be measured by flow-cytometry (cluster of differentiation (CD) 41, CD 42, CD 62, CD 63), which allows detection of surface antigens in a sensitive and specific manner. This study aimed to describe platelets activity in T2DM in association with cardiovascular and cerebrovascular complications in relation to duration of diabetes (DM).

View Article and Find Full Text PDF

Cisplatin is an antineoplastic drug that exhibits toxicity dependent on dosage and has adverse reproductive effects. (Bitter melon) is a natural vegetable plant; its active ingredients possess antioxidant, apoptotic, antiproliferative, hypoglycemic, and other therapeutic properties. This study evaluates the effect of the administration of bitter melon extract, cisplatin, and cisplatin/bitter melon cotreatment on liver and kidney functions, serum and testicular oxidative status, testis histology, and sperm parameters.

View Article and Find Full Text PDF

Alzheimer's disease (AD) is the leading cause of dementia worldwide, and the development of early screening methods can address its significant health and social consequences. In this paper, we present a rotary-valve assisted paper-based immunoassay device (RAPID) for early screening of AD, featuring a highly integrated on-chip rotary micro-valve that enables fully automated and efficient detection of the AD biomarker (amyloid beta 42, Aβ42) in artificial plasma. The microfluidic paper-based analytical device (μPAD) of the RAPID pre-stores the required assay reagents on a μPAD and automatically controls the liquid flow through a single valve.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!