Objective The various formulae used for QT correction by heart rate (HR) require the execution of operations with the aid of calculators or applications. This study aimed to evaluate the performance of a simple rule for QTc estimation, comparing the measurements obtained with those provided by the commonly used equations of Bazett, Fridericia, Framingham, and Hodges. Methods We used the database of a previous observational study, which analyzed patients prospectively with acute pulmonary edema admitted in an emergency service. One hundred four patients were included for QTc assessment, of whom 86 patients underwent two ECG: one ECG <24h and other >24h after admission. Thus, a total of 190 ECGs were analyzed by two observers that manually measured QT and HR. QTc was obtained using the known formulae and the proposed equations: QTc = QT+2 (FC-60) for HR ≤ 90 bpm and QTc=QT+2(FC-60)-10 for HR>90 bpm. Results Bland-Altman plots show good agreement between the simple rule and Hodges equation, with a mean difference of -3,4, SD of 4.96 and 95% limits of agreement from -9,9 to 3.2. There was not a good agreement between the simple method and the other formulae. Conclusion The proposed method has good agreement with the measures of QTc by the equation of Hodges in the HR range of 40 to 130bpm in acutely ill patients. Our method may be a plausible option for quick QT correction in these subjects.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7810174PMC
http://dx.doi.org/10.7759/cureus.12122DOI Listing

Publication Analysis

Top Keywords

good agreement
12
simple rule
8
agreement simple
8
qtc
6
practical method
4
method qtc
4
qtc interval
4
interval measurement
4
measurement objective
4
objective formulae
4

Similar Publications

Rotational spectroscopy is an excellent tool for structure determination, which can provide additional insights into local electronic structure by investigating the hyperfine pattern due to nuclear quadrupole coupling. Jet-cooled molecules are good experimental benchmark targets for electronic structure calculations, as they are free of environmental effects. We report the rotational spectra of 2-chlorobenzaldehyde, 3-chlorobenzaldehyde, and 4-chlorobenzaldehyde, including a complete experimental description of the nuclear quadrupole coupling constants, which were previously not experimentally determined.

View Article and Find Full Text PDF

Background: Ultrasound based radiomics prediction model can improve the differentiation ability of benign and malignant thyroid nodules to avoid overtreatment. This study evaluates the role of predictive models based on intranodular and perinodular ultrasound radiomics in distinguishing between benign and malignant thyroid nodules.

Methods: A total of 1,076 thyroid nodules were enrolled from three hospitals between 2016 and 2022, forming the training, validation and test cohorts.

View Article and Find Full Text PDF

Objective: To test the hypothesis that step count based on a virtual 2-minute step test (2MST) predicts cardiorespiratory fitness (CRF).

Design: Cross-sectional study.

Setting: Veteran Affairs Medical Centers participating in a randomized trial of functional exercise training delivered by videoconferencing.

View Article and Find Full Text PDF

Imaging-based method to quantify left ventricular diastolic pressures.

Eur Heart J Cardiovasc Imaging

January 2025

School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.

Aim: To establish an imaging-based method to quantify left ventricular (LV) diastolic pressures.

Methods/results: In 115 patients suspected of coronary artery disease, LV pressure was measured by micromanometers and images by echocardiography. LV filling pressure was measured as LV pre-atrial contraction pressure (pre-A PLV).

View Article and Find Full Text PDF

Introduction: Surgical treatment of pelvic girdle pain (PGP) involves arthrodesis of sacroiliac (SI) and pubic symphysis joints. Fusion of pubic symphysis involves the implantation of an autologous iliac crest tricortical graft harvested from the iliac crest. The objective was to assess the safety of a novel synthetic graft substitute (b.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!