Radiation sensitivity was determined for nine University of Michigan squamous cell carcinoma (UM-SCC) cell lines, MCF-7 and HeLa, using a 96-well plate clonogenic assay. Plating efficiencies (PE) of the UM-SCC cell lines were between 0.16 and 0.36. Higher PE values obtained were with MCF-7 (0.4) and HeLa (0.5). The UM-SCC cell lines were used at low passages (passage 13 to passage 20) to minimize artifacts attributable to long-term culture. Cells were irradiated in suspension using a cobalt 60 gamma source at a dose rate of 0.94 Gy/min (94 rad/min). Survival data were fitted well by either a linear quadratic function F = e-(alpha D + beta D2) or by a monoexponential function F = Ae-alpha D. Mean inactivation dose, equivalent to the area under the survival curve (AUC), was used as a measure of radiation sensitivity. The UM-SCC-1, 9, 11A, 11B, MCF-7, and HeLa were the most radiation resistant lines we tested (AUC greater than 2.1), while UM-SCC-14A was the most sensitive (AUC = 1.591). The assay was highly reproducible, and the difference in radiation sensitivity between cell lines were statistically significant.

Download full-text PDF

Source
http://dx.doi.org/10.1001/archotol.1988.01860160071024DOI Listing

Publication Analysis

Top Keywords

cell lines
16
radiation sensitivity
12
um-scc cell
12
mcf-7 hela
12
96-well plate
8
plate clonogenic
8
squamous cell
8
cell carcinoma
8
cell
7
lines
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!