Acrochordon (skin tag) removal by snip excision is a routine dermatologic procedure. Bleeding is a common sequelae of snip excision that requires hemostatic control. Chemical cautery is a common means of achieving hemostasis in this procedure. The aim of this study was to evaluate three different chemical cautery solutions for their time to hemostasis, pain upon application, and associated pigmentary changes. Twelve patients with six or more skin tags on the bilateral neck and/or axilla were enrolled. Two skin tags were cauterized with ferric subsulfate solution, two with silver nitrate, and two with aluminum chloride hexahydrate solution. Time to hemostasis and pain with application of each cautery solution to the skin tag was recorded. At a two-week follow-up appointment, patient satisfaction was assessed with a survey, and pigmentary changes were documented with digital photography. There was no significant variability in the time to hemostasis among the three chemical cautery solutions (=0.57). Pain response was significantly different among the three solutions (=0.003). Compared to silver nitrate (median=6.00, interquartile range [IQR]: 4.50-6.50), aluminum chloride hexahydrate (median=1.00, IQR: 0.50 to 6.00; Sidak =0.02) and ferric subsulfate (median=1.50, IQR: 0.00-3.50; Sidak =0.01) had a significantly lower pain response. Among participants, three (25%) experienced a pigmentary change with ferric subsulfate, two (17%) with aluminum chloride, and six (50%) with silver nitrate (overall = 0.14). These results indicate that the three standard chemical cautery solutions for skin tag snip excision have significant differences in pain upon application and pigmentary changes. This might be a relevant consideration when selecting a chemical cautery solution.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7819594PMC

Publication Analysis

Top Keywords

chemical cautery
20
ferric subsulfate
16
silver nitrate
16
aluminum chloride
16
time hemostasis
16
snip excision
16
skin tag
12
cautery solutions
12
pain application
12
pigmentary changes
12

Similar Publications

Introduction And Objectives: This study aimed to investigate the prevalence of recurrent and active epistaxis in adult patients presenting to the Emergency Department (ED) and explored the association of recurrent epistaxis with demographic characteristics, comorbidities and medications, and types of emergency interventions in adult epistaxis patients.

Methods: A retrospective cross-sectional study was conducted with data from Eds of two tertiary hospitals over three years, from January 2019 to January 2022. All adult patients aged ≥18 years with active epistaxis not resolved by pressure on the nose or head positioning were included.

View Article and Find Full Text PDF

The reuse of electro-coagulated sludge as an adsorbent for Cr(VI) ion reduction was investigated in this study. Electro-coagulated sludge was obtained during the removal of citric acid wastewater by the electrocoagulation process. The following parameters were optimized for Cr(VI) reduction: pH (5-7), initial Cr(VI) concentration (10-50 mg/L), contact time (10-45 min), and adsorbent dosage (0.

View Article and Find Full Text PDF

Giant conjunctival cysts, though rare, can cause significant discomfort and functional impairment due to their size as well as their potential for rupture and recurrence. We report the case of a 51-year-old female who presented with a recurrent giant conjunctival cyst in her left eye, experiencing considerable discomfort and pain upon eye movement. The cyst, located in the left eye, had previously recurred after surgical excision, though visual acuity remained 20/20 bilaterally.

View Article and Find Full Text PDF

Objective: This study aims to observe the clinical efficacy of single-incision thoracoscopic bullectomy combined with C-shaped electrocautery pleurodesis compared to traditional iodine chemical pleurodesis in the treatment of patients with spontaneous pneumothorax.

Methods: A total of 128 patients with spontaneous pneumothorax who underwent surgical treatment at our institution from January 2021 to December 2022 were selected. Patients were categorized into the study group ( = 65) and the control group ( = 63) based on the surgical method used.

View Article and Find Full Text PDF
Article Synopsis
  • This study explores the use of micro-inter-electrode distances in electrocoagulation to enhance treatment and energy efficiency for low-conductivity laundry wastewater.
  • The research analyzed how different interelectrode distances, current densities, and anode materials impacted the removal rates of pollutants like paracetamol and total organic carbon.
  • Findings show that while micro-distances reduced energy consumption significantly, they also resulted in increased sludge production, highlighting a trade-off in using different electrode materials for optimal performance.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!