Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A low-voltage nongassing electroosmotic pump was assembled by sandwiching a silica frit between two carbon paper electrodes that were dip-coated with a paste consisting of phosphomolybdic acid/phosphotungstic acid (PMA/PTA)-encapsulated multiwalled carbon nanotubes (MWCNTs) and Nafion. The PMA/PTA encapsulation was a combined effect of their thermomigration and nanocapillary action in MWCNTs. The encapsulated MWCNTs retained desirable redox and charge transfer characteristics of PMA/PTA. The stable voltammogram in 1 M HSO solution exhibited 77% charge retention. A total of three different possible pump configurations, namely, PUMP-I = PMA//SiO//PMA, PUMP-II = PTA//SiO//PTA, and PUMP-III = PMA//SiO//PTA were put together. They are in the sequence of the anode, silica frit, and cathode. All pumps showed a linear dependence on the flow rate with a minimum operating voltage of 1 V, which is well below the thermodynamic potential of water splitting. PUMP-I provided an electroosmotic flux of 43.57 μLmin V cm that matched the requirement of an infusion device like an insulin pump. The device was fabricated and its applicability has been demonstrated by delivering ∼1.8 mL of water at a 10 ± 2 μLmin flow rate at 2 V constant applied voltage over a period of 3 h. Such a wearable device can be programed to deliver model insulin or pain medication drugs for chronic diseases.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acs.langmuir.0c03196 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!