Objective: To develop a robust amine chemical exchange saturation transfer (CEST) physical phantom, validate the temporal stability, and create a supporting software for automatic image processing and quality assurance.
Materials And Methods: The phantom was designed as an assembled laser-cut acrylic rack and 18 vials of phantom solutions, prepared with different pHs, glycine concentrations, and gadolinium concentrations. We evaluated glycine concentrations using ultraviolet absorbance for 70 days and measured the pH, relaxation rates, and CEST contrast for 94 days after preparation. We used Spearman's correlation to determine if glycine degraded over time. Linear regression and Bland-Altman analysis were performed between baseline and follow-up measurements of pH and MRI properties.
Results: No degradation of glycine was observed (p > 0.05). The pH and MRI measurements stayed stable for 3 months and showed high consistency across time points (R = 1.00 for pH, R, R, and CEST contrast), which was further validated by the Bland-Altman plots. Examples of automatically generated reports are provided.
Discussion: We designed a physical phantom for amine CEST-MRI, which is easy to assemble and transfer, holds 18 different solutions, and has excellent short-term chemical and MRI stability. We believe this robust phantom will facilitate the development of novel sequences and cross-scanners validations.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10334-020-00902-z | DOI Listing |
Cureus
December 2024
Neurological Surgery, Jersey Shore Medical Center, Neptune, USA.
Introduction The Synaptive magnetic resonance imaging (MRI) system (Synaptive Medical, Toronto, Canada) is a midfield 0.5 T head-only scanner for imaging the head and neck in adults and pediatrics. The system received US FDA and Health Canada clearance for clinical use in 2020.
View Article and Find Full Text PDFHealth Expect
February 2025
Department of Behavioural Sciences, Kwame Nkrumah University of Science and Technology, Kumasi, Ghana.
Introduction: Physical and emotional loss from amputation and associated physical disability are associated with adverse physical and psychological experiences. However, little research, within the Ghanaian context, has focused on the impact of amputation on the well-being of amputees and their caregivers and the coping strategies they use to mitigate challenges experienced. Therefore, the present study explored the impact of amputation on the well-being of amputees and caregivers, and the coping strategies they employ to manage distress associated with amputation and caregiving.
View Article and Find Full Text PDFJ Biomed Opt
June 2024
Food and Drug Administration, Center for Devices and Radiological Health, Silver Spring, Maryland, United States.
Significance: Pulse oximeter measurements are commonly relied upon for managing patient care and thus often require human testing before they can be legally marketed. Recent clinical studies have also identified disparities in their measurement of blood oxygen saturation by race or skin pigmentation.
Aim: The development of a reliable bench-top performance test method based on tissue-simulating phantoms has the potential to facilitate pre-market assessment and the development of more accurate and equitable devices.
Eur J Nucl Med Mol Imaging
January 2025
Department of Radiology, UC Davis Health, Sacramento, CA, 95817, USA.
Medicina (Kaunas)
December 2024
Department of Biomechanics and Kinesiology, Institute of Physiotherapy, Faculty of Health Sciences, Jagiellonian University Medical College, 8 Skawińska Street, 31-066 Krakow, Poland.
: Amputation poses a significant clinical and therapeutic challenge, with over 90.0% of amputations involving the lower limbs, of which 75.0% are associated with diabetes and peripheral artery disease.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!