A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Source characterization and health risks of BTEX in indoor/outdoor air during winters at a terai precinct of North India. | LitMetric

Source characterization and health risks of BTEX in indoor/outdoor air during winters at a terai precinct of North India.

Environ Geochem Health

Environmental Research Lab, Department of Chemistry, St. Andrew's College, Gorakhpur, India.

Published: August 2021

BTEX are the consistently found air contaminants in indoor and outdoor environments. In order to investigate the exposure levels of BTEX, the indoor and outdoor air was analyzed during winter season at homes located at four selected sites of Gorakhpur, Uttar Pradesh, India, which comprised residential, roadside, industrial and agricultural areas. BTEX were sampled with a low-flow pump (SKC model 220). Samples were extracted with CS and the aromatic fraction was subjected to GC-FID. Mean indoor concentration of BTEX was highest at the agricultural (70.9 µg m) followed by industrial (30.0 µg m), roadside (17.5 µg m) and residential site (11.8 µg m). At outdoor locations, the mean BTEX levels were highest at the roadside (22.0 µg m) followed by industrial (18.7 µg m), agricultural (11.0 µg m) and residential site (9.1 µg m). The I/O ratios were greater than 1 at all the sites except roadside site, where I/O ratios for toluene, ethylbenzene and xylene were less than unity. Poor correlation between indoor and outdoor levels at each site further indicated the dominance of indoor sources. Factor analysis followed by one-way analysis of variance depicts that the presence of BTEX compounds at all the sites indicate a mixture of vehicular and combustion activities. For benzene, the ILTCR values exceeded the safe levels, whereas ethylbenzene was nearby to the recommended level 1 × 10. The HQ values were above unity for agricultural (indoors) and industrial (outdoors) as an exception to all the other sites which indicted the value below unity.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10653-021-00822-4DOI Listing

Publication Analysis

Top Keywords

indoor outdoor
12
residential site
8
i/o ratios
8
btex
7
indoor
5
source characterization
4
characterization health
4
health risks
4
risks btex
4
btex indoor/outdoor
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!