Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: To evaluate the diagnostic performance and reliability of magnetic resonance of arthrography (MRA) in diagnosis of subscapularis (SSC) tendon tears between two reviewers with varying levels of experience, and compare the results with clinical tests.
Materials And Methods: SSC tendons were retrospectively evaluated in a total of 272 patients with arthroscopic confirmations. A total of 548 shoulder MRAs were evaluated by two musculoskeletal radiologists, and SSC tendon pathologies were classified into three groups: intact tendon (n = 149), partial-thickness tear (n = 92), or full-thickness tear (n = 31). Diagnostic performance was determined using arthroscopy as gold standard and compared with results of four clinical tests. Intra- and inter-observer reliabilities of two reviewers were evaluated using kappa statistics.
Results: For full-thickness tears, mean values of sensitivity, specificity, and accuracy of reviewer 1/reviewer 2 were 71.0%/87.1%, 97.3%/98.3%, and 94.4%/95.5%, respectively. For partial-thickness tears, mean values of sensitivity, specificity, and accuracy were 72.8%/73.4%, 78.3%/81.2%, and 76.5%/78.5%, respectively. Intra- and inter-observer reliabilities for both reviewers were good to very good (k = 0.85/0.93, p < 0.001; k = 0.74-0.89, p < 0.001). For all clinical tests, while specificity was very high, sensitivity was very low and the overall accuracy was also low.
Conclusion: MRA showed high diagnostic performance for the diagnosis of SSC tendon tears, especially full-thickness tears, with good inter- and intra-observer reliabilities, regardless of the level of experience of the reviewer.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00256-020-03697-1 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!