Introduction: In a secondary analysis of our published data demonstrating compensatory vaping behavior (increased puff number, puff duration, and device power) with e-cigarettes refilled with low versus high nicotine concentration e-liquid, here we examine 5-day time course over which compensatory behavior occurs under fixed and adjustable power settings.
Aims And Methods: Nineteen experienced vapers (37.90 ± 10.66 years, eight females) vaped ad libitum for 5 consecutive days under four counterbalanced conditions (ie, 20 days in total): (1) low nicotine (6 mg/mL)/fixed power (4.0 V/10 W); (2) low nicotine/adjustable power; (3) high nicotine (18 mg/mL)/fixed power; (4) high nicotine/adjustable power (at 1.6 Ohm). Puff number, puff duration, and power settings were recorded by the device. For each day, total daily puffing time was calculated by multiplying daily puff number by mean daily puff duration.
Results: A significant day × setting interaction revealed that whilst puffing compensation (daily puffing time) continued to increase over 5 days under fixed power, it remained stable when power settings were adjustable. Separate analysis for puff number and puff duration suggested that the puffing compensatory behavior was largely maintained via longer puff duration.
Conclusions: Under fixed power conditions (4.0 V/10 W), vapers appear to compensate for poor nicotine delivery by taking longer puffs and this compensatory puffing appears to be maintained over time.
Implications: Studies in smokers suggest that when switching to lower nicotine levels, compensation for poorer nicotine delivery is transient. Our novel findings suggest that vapers show a different pattern of compensation which is influenced by both nicotine strength and device power settings. When power is fixed (4.0 V; 10 W), compensation (via more intensive puffing) appears prolonged, persisting up to 5 days. Under adjustable settings when power is increased, puffing patterns remain stable over time. Implications of such compensatory behaviors for product safety and user satisfaction need further exploration.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8186419 | PMC |
http://dx.doi.org/10.1093/ntr/ntab013 | DOI Listing |
Pilot Feasibility Stud
January 2025
School of Medicine, University of Limerick, Limerick, Ireland.
Background: Stroke has devastating consequences for survivors. Hypertension is the most important modifiable risk factor, and its management largely takes place in primary care. However, most stroke-based research does not occur in this setting.
View Article and Find Full Text PDFChild Abuse Negl
January 2025
Hebrew University of Jerusalem, Israel. Electronic address:
Background: Child Protection Legal Systems around the world work to toe the line between protecting children from possible harms and avoiding inflicting further harm by mistreating or misrecognizing the problems the children in question are facing. Despite growing efforts to enhance children's participation in child protection proceedings, there is still a lot of criticism from families and children directed at the state and the legal system.
Objective: This inquiry attempts to locate at least one of the reasons for such criticism - the feeling of being excluded from the decision-making process.
Stat Med
February 2025
U.S. Food and Drug Administration, Silver Spring, Maryland.
The recent U.S. Food and Drug Administration guidance on complex innovative trial designs acknowledges the use of Bayesian strategies to incorporate historical information based on clinical expertise and data similarity.
View Article and Find Full Text PDFSensors (Basel)
January 2025
CAS Center for Excellence in Superconducting Electronics (CENSE), Shanghai Institute of Microsystem and Information Technology (SIMIT), Chinese Academy of Sciences, Shanghai 200050, China.
Generally, the electrocardiography (ECG) system plays an important role in preventing and diagnosing heart diseases. To further improve the amenity and convenience of using an ECG system, we built a customized capacitive electrocardiography (cECG) system with one wet electrode, sixteen non-contact electrodes, two ADS1299 chips, and one STM32F303-based microcontroller unit (MCU). This new cECG system could acquire, save, and display the ECG data in real time.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Department of Economics and Management, Russian University of Cooperation, 420034 Kazan, Russia.
The process of establishing relay protection and automation (RPA) settings for electric power systems (EPSs) entails complex calculations of operating modes. Traditionally, these calculations are based on symmetrical components, which require the building of equivalent circuits of various sequences. This approach can lead to errors both when identifying the operating modes and when modeling the RPA devices.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!