Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The association between severe adverse events (SAEs) and prior radiotherapy or stent type remains controversial. Patients with esophageal or esophagogastric junctional cancer who underwent stent placement (2005-2019) were enrolled in this retrospective study conducted at a tertiary cancer institute in Japan. The exclusion criteria were follow-up period of < 1 month and insufficient data on stent type or cancer characteristics. We used Mann-Whitney's U test for quantitative data and Fisher's exact test for categorical data. Multivariate analysis was performed using a logistic regression model. 107 stents were placed. Low radial-force stents (L group) were used in 51 procedures and high radial-force stents (H group) in 56 procedures. SAEs developed after nine procedures, the median interval from stent placement being 6 days (range, 1-141 days). SAEs occurred more frequently in the H (14%: 8/56) than in the L group (2%: 1/51) (P = 0.03). In patients who had undergone prior radiotherapy, SAEs were more frequent in the H (36%: 4/11) than in the L group (0%: 0/13) (P = 0.03). Re-obstruction and migration occurred after 16 and three procedures, respectively; these rates did not differ significantly between groups (P = 0.59, P = 1, respectively). Low radial-force stents may reduce the risk of SAEs after esophageal stenting.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7822838 | PMC |
http://dx.doi.org/10.1038/s41598-021-81763-x | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!