A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Experimental evaluation of direct thromboaspiration efficacy according to the angle of interaction between the aspiration catheter and the clot. | LitMetric

Background: Successful direct thromboaspiration (DTA) is related to several factors such as clot consistency, size, and location. It has also been demonstrated recently that the angle of interaction (AOI) formed by the aspiration catheter and the clot is related to DTA efficacy. The aims of this study were three-fold: (a) to confirm the clinical finding that the AOI formed by the aspiration catheter and the clot influence DTA efficacy; (b) to evaluate to what extent this influence varies according to differences in clot consistency and size; and (c) to validate stent retriever thrombectomy as an effective rescue treatment after DTA failure in the presence of an unfavorable AOI.

Methods: A rigid vascular phantom designed to reproduce a middle cerebral artery trifurcation anatomy with three M2 segments forming different angles with M1 and thrombus analog of different consistencies and sizes was used.

Results: DTA was highly effective for AOIs >125.5°, irrespective of thrombus analog features. However, its efficacy decreased for acute AOIs. Rescue stent retriever thrombectomy was effective in 92.6% of cases of DTA failure.

Conclusions: This in vitro study confirmed that the AOI formed by the aspiration catheter and the thrombus analog influenced DTA efficacy, with an AOI >125.5° related to an effective DTA. Stent retriever thrombectomy was an effective rescue treatment after DTA failure, even in the presence of an unfavorable AOI.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8606460PMC
http://dx.doi.org/10.1136/neurintsurg-2020-016889DOI Listing

Publication Analysis

Top Keywords

aspiration catheter
16
catheter clot
12
aoi formed
12
formed aspiration
12
dta efficacy
12
stent retriever
12
retriever thrombectomy
12
thrombectomy effective
12
thrombus analog
12
dta
9

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!