Background: Initial stability of uncemented acetabular components in total hip arthroplasty (THA) is important for osseointegration and potentially enhanced by screw fixation. We used Australian Orthopaedic Association National Joint Replacement Registry data to determine whether screw usage influences uncemented acetabular component survival.
Methods: Primary THA with uncemented acetabular components performed for osteoarthritis from 1999 to 2018 was included. Survivorship was calculated using Kaplan-Meier estimates of cumulative percent revision (CPR). Comparisons used Cox proportional hazards method. An instrumental variable analysis adjusted for surgeon preference for screws as a confounding factor was used.
Results: Three hundred thirty thousand one hundred ninety-two THAs were included (31.8% with screws, 68.2% without). Two hundred twenty thousand six hundred seven were included in the instrumental variable analysis. Revision rate of acetabular components (all causes) was higher with screws during the first six years (hazard ratio (HR) = 1.45 (95% CI 1.34, 1.57), p < 0.001) and lower thereafter (HR = 0.81 (95% CI 0.67, 0.98), p = 0.027). Revision rate of acetabular components for loosening was higher with screws over the entire study period (HR = 1.73 (95% CI 1.51, 1.98), p < 0.001). Overall THA revision rate was higher with screws during the first six years (HR = 1.20 (95% CI 1.15, 1.26), p < 0.001) but lower thereafter (HR = 0.89 (95% CI 0.81, 0.98), p = 0.020). Revision rate for dislocation was higher with screws over the entire period (HR = 1.16 (95% CI 1.06, 1.26), p < 0.001). Instrumental variable analysis revealed higher revision rates with acetabular screws in the first six years. (HR = 1.18 (95% CI 1.09-1.29), p < 0.001).
Conclusion: Screws did not confer a protective effect against acetabular loosening and were not associated with long-term negative consequences.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00264-021-04949-y | DOI Listing |
Hip Int
January 2025
Orthopaedic Clinic Lucerne, Lucerne, Switzerland.
Introduction: The RM Pressfit vitamys is an uncemented, titanium particle-coated, isoelastic monoblock cup made of vitamin E blended highly cross-linked polyethylene. We addressed the following questions: (1) What are the clinical and (2) radiographic outcomes 10 years after implantation? (3) What is the revision rate?
Methods: In this prospective observational study in a tertiary care centre we investigated all consecutive cases of total hip replacement with the RM Pressfit vitamys cup between September 2009 and November 2011. It was implanted in 162 hips, 49.
Hip Int
January 2025
Department of Orthopaedic Surgery, Hospital de Sant Pau (HSCSP), Barcelona, Spain.
Background: Survival at 25 years' follow-up for total hip arthroplasty (THA) has been reported at 5%-77%, with hydroxyapatite (HA) coating, due to its osteo-conductive properties, used to enhance implant fixation and survival. The progressive increase in life expectancy raises doubts regarding HA-coated THA survival and THA revision surgery risk. The aim of our study was to retrospectively analyse survival for primary uncemented fully HA-coated THA after 28 years' follow-up.
View Article and Find Full Text PDFCureus
November 2024
Trauma and Orthopaedics, North Manchester General Hospital, Manchester, GBR.
Introduction: Salvage arthroplasty for failed proximal femoral fracture fixation is a complex procedure. This involves the removal of the primary failed or broken implant followed by a hip joint replacement procedure. The complications and technical difficulties associated with these surgeries are often difficult to anticipate.
View Article and Find Full Text PDFJ Orthop Case Rep
December 2024
Department of Orthopaedics, AIIMS Raebareli, Raebareli, Uttar Pradesh, India.
Introduction: Metallosis, characterized by the collection of metallic debris in periarticular tissues, is primarily associated with metal-on-metal bearings in hip arthroplasty. This report presents a rare case of metallosis after metal-on-polyethylene (MoP) total hip arthroplasty (THA), highlighting diagnostic challenges and management strategies. Metallosis following MoP arthroplasty is extremely rare, with only a limited number of documented cases in the literature.
View Article and Find Full Text PDFJ Arthroplasty
November 2024
Nottingham Elective Orthopaedic Services, Nottingham University Hospitals, Nottingham, United Kingdom; University of Nottingham, Nottingham, United Kingdom.
Background: Trabecular metal is being increasingly used in primary total hip arthroplasty (THA). This study compared medium-term (< 15 years) outcomes of fiber mesh titanium and trabecular metal acetabular components.
Methods: This study included 6,563 patients who underwent primary THA with either fiber mesh titanium or trabecular metal-backed acetabular components.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!