Femtosecond laser electronic excitation tagging (FLEET) velocimetry was used to study the flowfield around a symmetric, transonic airfoil in the NASA Langley 0.3-m TCT facility. A nominal Mach number of 0.85 was investigated with a total pressure of 125 kPa and total temperature of 280 K. Two-components of velocity were measured along vertical profiles at different locations above, below, and aft of the airfoil at angles of attack of 0°, 3.5°, and 7°. Velocity profiles within the wake showed sufficient accuracy, precision, and sensitivity to resolve both the mean and fluctuating velocities and general flow physics such as shear layer growth. Evidence of flow separation is found at high angles of attack. Velocity measurements were assessed for their accuracy, precision, dynamic range, spatial resolution, and overall measurement uncertainty as they relate to the present experiments. Measurement precisions as low as 1 m/s were observed, while the velocity dynamic range was found to be nearly a factor of 500. The spatial resolution of between 1 mm and 5 mm was found to be primarily limited by the FLEET spot size and advection of the flow. Overall measurement uncertainties ranged from 3 to 4 percent.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7816839 | PMC |
http://dx.doi.org/10.2514/1.J056154 | DOI Listing |
Eur J Prev Cardiol
January 2025
Department of Cardiology, Kailuan General Hospital, Tangshan 063001, Hebei, CN.
Background: The precise pathways connecting insulin resistance (IR) to atherosclerotic cardiovascular disease (ASCVD) remain undefined. The present study aimed to examine the mediating role of arterial stiffness in the association between IR and ASCVD, providing epidemiology insights into the potential mechanisms driving IR to incident ASCVD.
Methods: A total of 59,777 participants from the Kailuan Study Arterial Stiffness Subcohort who were free of ASCVD at baseline were enrolled in the present study.
Methods Protoc
January 2025
Faculty of Health Science, International University Isabel I of Castile, 09003 Burgos, Spain.
This study evaluated the concurrent validity of the Vitruve linear encoder compared to the T-Force device for measuring mean propulsive velocity (MPV) and peak velocity (PV) during the free-weight bench press exercise. Thirteen resistance-trained men participated in three sessions, during which MPV and PV were recorded simultaneously by both devices. The data were analysed using one-way ANOVA, Pearson's correlation, Bland-Altman analysis, and effect size calculations, with statistical significance set at ≤ 0.
View Article and Find Full Text PDFJ Funct Morphol Kinesiol
January 2025
Department of Sports Training Science-Combats, National Taiwan Sport University, Taoyuan City 333, Taiwan.
Background/objectives: The underlying mechanisms of taekwondo-specific jumping ability among different competition levels are still unknown. This study aimed to compare vertical and horizontal stretch-shortening cycle (SSC) performance between athletes of different competitive levels and examine the relationships of force and power production abilities between those two directions in Taiwanese collegiate-level male taekwondo athletes.
Methods: Seventeen male collegiate taekwondo athletes were divided into two groups: medalists (MG, n = 8) and non-medalists (NMG, n = 9); both groups performed countermovement jumps (CMJ) on a force platform and single-leg lateral hops (SLLHs) via an optoelectronic measurement system.
Vision (Basel)
January 2025
Centre Gilles Gaston Granger, UMR 7304 Centre National de la Recherche Scientifique, Aix Marseille Université, 13621 Aix-en-Provence, France.
The appearance of an object triggers an orienting gaze movement toward its location. The movement consists of a rapid rotation of the eyes, the saccade, which is accompanied by a head rotation if the target eccentricity exceeds the oculomotor range and by a slow eye movement if the target moves. Completing a previous report, we explain the numerous points that lead to questioning the validity of a one-to-one correspondence relation between measured physical values of gaze or head orientation and neuronal activity.
View Article and Find Full Text PDFActa Radiol
January 2025
Department of Radiology, Interventional Radiology, Sağlık Bilimleri Üniversitesi Ankara Dışkapı Yıldırım Beyazıt Eğitim ve Araştırma Hastanesi, Ankara, Türkiye.
Background: Carotid artery stenting (CAS) is an interventional management in preventing ischemic stroke caused by carotid artery stenosis. After the treatment with CAS, in-stent restenosis caused by neointimal hyperplasia may develop.
Purpose: This study aims to obtain a better determination of neointimal hyperplasia using superb microvascular imaging (SMI), which provides a high-quality visualization of the endoluminal lesions, and to compare these results with B-mode and Doppler ultrasound (US).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!