Tailored Vessel-Catheter Diameter Ratio in a Direct Aspiration First-Pass Technique: Is It a Matter of Caliber?

AJNR Am J Neuroradiol

From the Department of Diagnostic, Unità Operativa Complessa of Neuroradiology and Interventional Neuroradiology (E.P., S.F., G.D.R., L.B., A.S., A.V., A.P., E.C.).

Published: March 2021

Background And Purpose: The aspiration technique has gained a prominent role in mechanical thrombectomy. The thrombectomy goal is successful revascularization (modified TICI ≥ 2b) and first-pass effect. The purpose of this study was to evaluate the impact of the vessel-catheter ratio on the modified TICI ≥ 2b and first-pass effect.

Materials And Methods: This was a retrospective, single-center, cohort study. From January 2018 to April 2020, 111/206 (53.9%) were eligible after applying the exclusion criteria. Culprit vessel diameters were measured by 2 neuroradiologists, and the intraclass correlation coefficient was calculated. The receiver operating characteristic curve was used for assessing the vessel-catheter ratio cutoff for modified TICI ≥ 2b and the first-pass effect. Time to groin puncture and fibrinolysis were weighted using logistic regression. All possible intervals (interval size, 0.1; sliding interval, 0.01) of the vessel-catheter ratio were plotted, and the best and worst intervals were compared using the χ test.

Results: Modified TICI ≥ 2b outcome was achieved in 75/111 (67.5%), and first-pass effect was achieved in 53/75 (70.6%). The MCA diameter was 2.1 mm with an intraclass correlation coefficient of 0.92. The optimal vessel-catheter ratio cutoffs for modified TICI ≥ 2b were ≤1.51 (accuracy = 0.67; 95% CI, 0.58-0.76; = 0.001), and for first-pass effect, they were significant (≤1.33; = .31). The modified TICI ≥ 2b odds ratio and relative risk were 9.2 (95% CI, 2.4-36.2; = 0.002) and 3.2 (95% CI, 1.2-8.7; = .024). The odds ratio remained significant after logistic regression (7.4; 95% CI, 1.7-32.5; = .008). First-pass effect odds ratio and relative risk were not significant (2.1 and 1.5; > .05, respectively). The modified TICI ≥ 2b best and worst vessel-catheter ratio intervals were not significantly different (55.6% versus 85.7%, = .12). The first-pass effect best vessel-catheter ratio interval was significantly higher compared with the worst one (78.6% versus 40.0%, = .03).

Conclusions: The aspiration catheter should be selected according to culprit vessel diameter. The optimal vessel-catheter ratio cutoffs were ≤1.51 for modified TICI ≥ 2b with an odds ratio of 9.2 and a relative risk of 3.2.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7959421PMC
http://dx.doi.org/10.3174/ajnr.A6987DOI Listing

Publication Analysis

Top Keywords

modified tici ≥ 2b
32
vessel-catheter ratio
28
odds ratio
16
ratio
12
tici ≥ 2b first-pass
12
ratio relative
12
relative risk
12
first-pass
8
modified
8
tici ≥ 2b
8

Similar Publications

Background: Lenvatinib is an oral tyrosine kinase inhibitor that selectively inhib-its receptors involved in tumor angiogenesis and tumor growth. It is an emerging first-line treatment agent for hepatocellular carcinoma (HCC). However, there is no intravenous ad-ministration of Lenvatinib.

View Article and Find Full Text PDF

Background: Breast cancer is a frequently diagnosed malignant disease and the primary cause of mortality among women with cancer worldwide. The therapy options are influenced by the molecular subtype due to the intricate nature of the condition, which consists of various subtypes. By focusing on the activation of receptors, Epidermal Growth Factor Receptor (EGFR) tyrosine kinase can be utilized as an effective drug target for therapeutic purposes of breast cancer.

View Article and Find Full Text PDF

Background: Hot-melt Pressure-sensitive Adhesives (HMPSA) are eco-friendly pressuresensitive adhesives, with the potential of being used as substrates for transdermal patches. However, due to the low hydrophilicity of HMPSA, the application is limited in the field of Traditional Chinese Medicine (TCM) plasters.

Methods: Three modified HMPSA were prepared with acrylic resin EPO, acrylic resin RL100, and Polyvinylpyrrolidone (PVP) as the modifying materials.

View Article and Find Full Text PDF

Impact of climate change that stems from gaseous emissions require sustainable materials to eliminate sulfur.  This study involves the modification of humic acid with magnetite nanoparticles (Fe₃O₄ NPs) by a microwave-assisted synthesis of an absorbent with reasonable pore volume and diameter for elimination of thiophenic compounds from fuel. The magnetic nano adsorbent designated Fe3O4@HA was characterized using advanced spectroscopic techniques, while their structure and morphology were analyzed through DLS, XPS, XRD, FT-IR, TGA, FESEM-EDX, VSM, and BET-N2 techniques.

View Article and Find Full Text PDF

Universal Construction of Electrical Insulation and High-Thermal-Conductivity Composites Based on the In Situ Exfoliation of Boron Nitride-Graphene Hybrid Filler.

ACS Appl Mater Interfaces

January 2025

Institute of Soft-matter and Advanced Functional Materials, Gansu Province Carbon New Material Industry Technology Center, School of Materials and Energy, Lanzhou University, Lanzhou 730000, China.

Hexagonal boron nitride (h-BN), with excellent thermal conductivity and insulation capability, has garnered significant attention in the field of electronic thermal management. However, the thermal conductivity of the h-BN-enhanced polymer composite material is far from that expected because of the insurmountable interfacial thermal resistance. In order to realize the high thermal conductivity of polymer composite thermal interface materials, herein, an in situ exfoliation method has been employed to prepare a boron nitride nanosheet-graphene (BNNS-Gr) hybrid filler.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!