Objectives: The aim of this study was to evaluate the short-term safety and efficacy of transcatheter aortic valve replacement (TAVR) with the LOTUS Edge system.
Background: The LOTUS Edge system was commercially re-released in April 2019. The authors report the first European experience with this device.
Methods: A multicenter, single-arm, retrospective registry was initiated to evaluate short-term clinical outcomes. Included cases are the first experience with this device and new implantation technique in Europe. Clinical, echocardiographic, and computed tomographic data were analyzed. Endpoints were defined according to Valve Academic Research Consortium-2 and were site reported.
Results: Between April and November 2019, 286 consecutive patients undergoing TAVR with the LOTUS Edge system at 18 European centers were included. The mean age and Society of Thoracic Surgeons score were 81.2 ± 6.9 years and 5.2 ± 5.4%, respectively. Nearly one-half of all patients (47.9%) were considered to have complex anatomy. Thirty-day major adverse events included death (2.4% [n = 7]) and stroke (3.5% [n = 10]). After TAVR, the mean aortic valve area was 1.9 ± 0.9 cm, and the mean transvalvular gradient was 11.9 ± 5.7 mm Hg. None or trace paravalvular leak (PVL) occurred in 84.4% and moderate PVL in 2.0%. There were no cases of severe PVL. New permanent pacemaker (PPM) implantation was required in 25.9% among all patients and 30.8% among PPM-naive patients.
Conclusions: Early experience with the LOTUS Edge system demonstrated satisfactory short-term safety and efficacy, favorable hemodynamic data, and very low rates of PVL in an anatomically complex cohort. New PPM implantation remained high. Further study will evaluate if increasing operator experience with the device and new implantation technique can reduce the incidence of PPM implantation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jcin.2020.09.044 | DOI Listing |
Gen Thorac Cardiovasc Surg Cases
December 2024
Department of Cardiovascular Surgery, National Cerebral and Cardiovascular Center, Osaka, 564-8565, Japan.
Background: With the rapid expansion of transcatheter aortic valve replacement (TAVR), TAVR valve explantation is also increasing. Nevertheless, previous reports on Lotus Edge valve explantation are limited to only two reports, none of which include intraoperative videos. Therefore, we report the case of an older adult who underwent a 2-year-old Lotus Edge valve explantation, after developing prosthetic valve endocarditis (PVE) and aortic annular abscess, with a strong indication for a TAVR explantation and surgical aortic valve replacement (AVR).
View Article and Find Full Text PDFAnal Methods
December 2024
School of Quality and Technical Supervision, Hebei University, Baoding, 071002, China.
A new technique has been developed to enhance the stability of laser-induced breakdown spectroscopy (LIBS) in the analysis of dry droplets by mitigating the coffee ring effect (CRE) on substrates with superhydrophobic microstructured grooves. The substrate was prepared from a laser-etched pure copper base, resembling the surface of a lotus leaf, creating a biomimetic superhydrophobic substrate. The superhydrophobic microstructured grooved substrate contained an array of dome-shaped cones with heights of approximately 140 μm and 100 μm, arranged in a periodic pattern of high-low-high.
View Article and Find Full Text PDFAm J Ophthalmol Case Rep
December 2024
Radical Health Tech, New Delhi, India.
Purpose: To compare the safety and efficacy of aflibercept with brolucizumab for recalcitrant diabetic macular edema (DME).
Observations: At week 52, no significant visual improvement was noted in the eyes treated with either brolucizumab ( = 0.527) or aflibercept ( = 0.
Comput Biol Med
September 2024
Department of Artificial Intelligence, Xiamen University, Xiamen, 361005, China. Electronic address:
Abdominal tumor segmentation is a crucial yet challenging step during the screening and diagnosis of tumors. While 3D segmentation models provide powerful performance, they demand substantial computational resources. Additionally, in 3D data, tumors often represent a small portion, leading to imbalanced data and potentially overlooking crucial information.
View Article and Find Full Text PDFLangmuir
July 2024
Key Laboratory of Bionic Engineering (Ministry of Education), Jilin University, Changchun 130022, P. R. China.
Biomimetic surfaces with special wettability have received much attention due to their promising prospects in droplet manipulation. Although some progress has been made, the manipulation of droplets by macroscopic defects of the millimeter structure and the wetting-state transition mechanism have rarely been reported. Herein, inspired by lotus leaves and desert beetles, biomimetic surfaces with macroscopic defects are prepared by laser processing and chemical modification.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!