Background: Electrical stimulation of residual afferent nerve fibers can evoke sensations from a missing limb after amputation, and bionic arms endowed with artificial sensory feedback have been shown to confer functional and psychological benefits. Here we explore the extent to which artificial sensations can be discriminated based on location, quality, and intensity.

Methods: We implanted Utah Slanted Electrode Arrays (USEAs) in the arm nerves of three transradial amputees and delivered electrical stimulation via different electrodes and frequencies to produce sensations on the missing hand with various locations, qualities, and intensities. Participants performed blind discrimination trials to discriminate among these artificial sensations.

Results: Participants successfully discriminated cutaneous and proprioceptive sensations ranging in location, quality and intensity. Performance was significantly greater than chance for all discrimination tasks, including discrimination among up to ten different cutaneous location-intensity combinations (15/30 successes, p < 0.0001) and seven different proprioceptive location-intensity combinations (21/40 successes, p < 0.0001). Variations in the site of stimulation within the nerve, via electrode selection, enabled discrimination among up to five locations and qualities (35/35 successes, p < 0.0001). Variations in the stimulation frequency enabled discrimination among four different intensities at the same location (13/20 successes, p < 0.0005). One participant also discriminated among individual stimulation of two different USEA electrodes, simultaneous stimulation on both electrodes, and interleaved stimulation on both electrodes (20/24 successes, p < 0.0001).

Conclusion: Electrode location, stimulation frequency, and stimulation pattern can be modulated to evoke functionally discriminable sensations with a range of locations, qualities, and intensities. This rich source of artificial sensory feedback may enhance functional performance and embodiment of bionic arms endowed with a sense of touch.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7819250PMC
http://dx.doi.org/10.1186/s12984-021-00808-4DOI Listing

Publication Analysis

Top Keywords

cutaneous proprioceptive
8
utah slanted
8
slanted electrode
8
electrode arrays
8
electrical stimulation
8
sensations missing
8
location quality
8
discriminability multiple
4
multiple cutaneous
4
proprioceptive hand
4

Similar Publications

Despite advances in understanding molecular and cellular changes in the aging nervous system, the upstream drivers of these changes remain poorly defined. Here, we investigate the roles of non-neural tissues in neuronal aging, using the cutaneous PVD polymodal sensory neuron in Caenorhabditis elegans as a model. We demonstrate that during normal aging, PVD neurons progressively develop excessive dendritic branching, functionally correlated with age-related proprioceptive deficits.

View Article and Find Full Text PDF

Imperceptible noisy galvanic vestibular stimulation (nGVS) improves standing balance due to the presence of stochastic resonance (SR). There is, however, a lack of consensus regarding the optimal levels and type of noise used to elicit SR like dynamics. We aimed to confirm the presence of SR behavior in the vestibular system of young healthy adults by examining postural responses to increasing amplitudes of white and pink noise stimulation scaled to individual cutaneous perceptual threshold.

View Article and Find Full Text PDF

We explored whether ankle torque variability or plantar perceptual threshold explains human balance control more effectively. We hypothesized that ankle torque variance is a better indicator of center of pressure (COP) velocity variance than plantar perceptual sensitivity. Two conditions were tested: loaded (23-kg vest added) and unloaded, as loading should diminish plantar sensitivity and increase COP velocity variability.

View Article and Find Full Text PDF

For the purpose of testing shoulder joint proprioception while controlling for axioscapular muscle recruitment, a novel shoulder thoracohumeral (TH) rotation joint position sense (JPS) measurement device was designed. This device was intended to measure shoulder TH rotation, while also implicitly constraining other upper limb degrees of freedom (DOF) and minimizing cutaneous sensation. The purpose of this study was to determine whether joint motion aside from shoulder TH rotation is being captured by the shoulder JPS measurement device.

View Article and Find Full Text PDF

Background: Beam walking is a highly studied assessment of walking balance. Recent research has demonstrated that brief intermittent visual rotations and occlusions can increase the efficacy of beam walking practice on subsequent beam walking without visual perturbations. We sought to examine the influence of full vision removal during practice walking on a treadmill-mounted balance beam.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!