A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A new transseptal solution for enabling left atrial access of large delivery sheaths. | LitMetric

A new transseptal solution for enabling left atrial access of large delivery sheaths.

J Cardiovasc Electrophysiol

Division of Cardiology, Vancouver General Hospital, University of British Columbia, Vancouver, British Columbia, Canada.

Published: March 2021

Background: Transseptal access for large sheaths may be encumbered by tissue resistance against the sheath-dilator stepped interface. The ExpanSure Large Access Transseptal Dilator (Baylis Medical) is designed as a single introducer and dilation device with a smooth sheath-dilator transition to support transseptal puncture. It may facilitate ease and efficiency of interatrial crossing.

Methods: This study experimentally evaluated the crossing force of ExpanSure relative to a conventional 8.5 F Swartz SL1 transseptal sheath and dilator in a benchtop septum model. Its ability to reduce the subsequent crossing force of a 14 F WATCHMAN delivery sheath was also tested. The clinical use of ExpanSure, including procedure time, was then validated in a series of left atrial appendage closure (LAAC) procedures.

Results: In a benchtop septum model (N = 12), less peak force (1.90 ± 0.08 N vs. 2.36 ± 0.09 N; p < .001) and overall work (17.3 ± 1.2 mJ vs. 28.0 ± 1.9 mJ; p < .001) were required to advance ExpanSure relative to a conventional SL1 transseptal sheath and dilator system. Peak force (2.34 ± 0.24 N vs. 2.65 ± 0.21 N; p < .003) and overall work (28.5 ± 3.9 mJ vs. 35.4 ± 2.1 mJ; p < .001) to advance a WATCHMAN sheath were also significantly lower after using ExpanSure than after using a conventional transseptal system. In 19 LAAC procedures, ExpanSure crossed the septum smoothly and integrated readily, which enabled efficient procedure completion (mean total procedure time 37.6 ± 13.5 min), with 100% success and no procedure-related complications.

Conclusion: Experimental force measurements, combined with early clinical experience using ExpanSure, suggest that the tapered design with smooth transition without dilator-sheath step-up and the larger diameter, both facilitated ease and efficiency of interatrial crossing.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jce.14903DOI Listing

Publication Analysis

Top Keywords

left atrial
8
access large
8
crossing force
8
benchtop septum
8
septum model
8
transseptal
5
transseptal solution
4
solution enabling
4
enabling left
4
atrial access
4