A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Development and Validation of a Novel Designer Benzodiazepines Panel by LC-MS-MS. | LitMetric

The Development and Validation of a Novel Designer Benzodiazepines Panel by LC-MS-MS.

J Anal Toxicol

NMS Labs, 200 Welsh Road, Willow Grove, PA 19044, USA.

Published: May 2021

Novel illicit benzodiazepines are among the most active areas of new illicit drug manufacture and use. We describe a method for the detection and quantification of etizolam and its metabolite α-hydroxyetizolam, flubromazolam, clonazolam, diclazepam, delorazepam, bromazepam, flubromazepam, phenazepam, flualprazolam, flunitrazolam, and nitrazolam in human whole blood. After addition of internal standards, samples are buffered and extracted using a liquid-liquid extraction. Analysis is performed using positive-ion electrospray tandem mass spectrometry for detection and quantitation. Calibration ranges were established based on the method performance and differed from compound to compound. Replicates at the lowest calibration point for each compound performed within 5% of CV (Coefficient of Variation). The correlation coefficient was >0.990 for all compounds. Relative standard deviation for all compounds was ≤10% of CV and accuracy was  ±10% for both within- and between-run experiments. The maximum average intra- and inter-run imprecision were 5.7%. The maximum average intra- and inter-run imprecision was -8.7%. As part of evaluating the scope for relevancy, samples testing positive in immunoassay but confirmed to be negative in traditional benzodiazepine confirmation method were re-analyzed using this method. The presence of at least one novel benzodiazepine was identified in 70% of these samples. The appearance of these novel "designer" benzodiazepines demonstrates the challenge for toxicology testing and the need for continually updated confirmation methods.

Download full-text PDF

Source
http://dx.doi.org/10.1093/jat/bkab013DOI Listing

Publication Analysis

Top Keywords

maximum average
8
average intra-
8
intra- inter-run
8
inter-run imprecision
8
development validation
4
novel
4
validation novel
4
novel designer
4
designer benzodiazepines
4
benzodiazepines panel
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!