A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Micro computed tomography evaluation of Invisalign aligner thickness homogeneity. | LitMetric

Objectives: To measure the thickness homogeneity of Invisalign (Align Technology Inc, San José, Calif) aligners with micro-computed tomography (micro-CT) scans.

Materials And Methods: Starting from micro-CT scanning of 20 different aligners, multiplanar reconstructions were obtained. An orthodontist blinded about the study measured aligner thickness in different regions (molar, canine, incisor) and in different sites (gingival-buccal, buccal, occlusal, lingual, and gingival-lingual). To assess various thicknesses in different aligner sites and regions, the sample was stratified into subgroups and linear regression analysis was performed.

Results: Descriptive analysis showed that mean thickness of aligners in the incisor region ranged from 0.582 mm to 0.639 mm, in the canine region from 0.569 mm to 0.644 mm, and in the molar region from 0.566 mm to 0.634 mm. Student's t-tests showed no significant differences in the aligner thickness of different regions when data were stratified by different sites. Student's t-tests showed significant differences in thickness homogeneity for the molar region when the data were stratified by tooth (mean difference = 0.068 mm; 95% confidence interval, 0.009-0.126 mm; P = .024).

Conclusions: Invisalign aligner thickness is characterized by small differences. The only significant difference was revealed in the molar region where thickness of the gingival-lingual edge is significantly thinner than that measured at the occlusal aspect. From a clinical perspective, the results of the present study could be considered to explain the reduced predictability of several orthodontic tooth movements in the molar region.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8084474PMC
http://dx.doi.org/10.2319/040820-265.1DOI Listing

Publication Analysis

Top Keywords

aligner thickness
16
molar region
16
thickness homogeneity
12
invisalign aligner
8
thickness
8
thickness regions
8
student's t-tests
8
t-tests differences
8
data stratified
8
region
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!