Background: The use of rapid diagnostic tests (RDTs) to diagnose malaria is common in sub-Saharan African laboratories, remote primary health facilities and in the community. Currently, there is a lack of reliable methods to ascertain health worker competency to accurately use RDTs in the testing and diagnosis of malaria. Dried tube specimens (DTS) have been shown to be a consistent and useful method for quality control of malaria RDTs; however, its application in National Quality Management programmes has been limited.
Methods: A Plasmodium falciparum strain was grown in culture and harvested to create DTS of varying parasite density (0, 100, 200, 500 and 1000 parasites/µL). Using the dried tube specimens as quality control material, a proficiency testing (PT) programme was carried out in 80 representative health centres in Togo. Health worker competency for performing malaria RDTs was assessed using five blinded DTS samples, and the DTS were tested in the same manner as a patient sample would be tested by multiple testers per health centre.
Results: All the DTS with 100 parasites/µl and 50% of DTS with 200 parasites/µl were classified as non-reactive during the pre-PT quality control step. Therefore, data from these parasite densities were not analysed as part of the PT dataset. PT scores across all 80 facilities and 235 testers was 100% for 0 parasites/µl, 63% for 500 parasites/µl and 93% for 1000 parasites/µl. Overall, 59% of the 80 healthcare centres that participated in the PT programme received a score of 80% or higher on a set of 0, 500 and 1000 parasites/ µl DTS samples. Sixty percent of health workers at these centres recorded correct test results for all three samples.
Conclusions: The use of DTS for a malaria PT programme was the first of its kind ever conducted in Togo. The ease of use and stability of the DTS illustrates that this type of samples can be considered for the assessment of staff competency. The implementation of quality management systems, refresher training and expanded PT at remote testing facilities are essential elements to improve the quality of malaria diagnosis.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7819240 | PMC |
http://dx.doi.org/10.1186/s12936-020-03569-y | DOI Listing |
Se Pu
January 2025
Research Center for Eco-Environmental Engineering, Dongguan University of Technology, Dongguan 523808, China.
Halogenated organic pollutants (HOPs) have attracted considerable attention owing to their persistence, bioaccumulation, and toxicity. The development of methods to detect HOPs in fish is challenging owing to the compositional complexity of fish matrices, which contain high levels of lipids and relatively low concentrations of HOPs. In addition, the lipophilicity of most HOPs renders their extraction difficult.
View Article and Find Full Text PDFClin Chim Acta
February 2025
Endocrine Laboratory, Department of Laboratory Medicine, Amsterdam UMC, Location University of Amsterdam, Amsterdam Gastroenterology Endocrinology & Metabolism, Meibergdreef 9, Amsterdam 1105 AZ, the Netherlands; Endocrine Laboratory, Department of Laboratory Medicine, Amsterdam UMC, Location Vrije Universiteit Amsterdam, Amsterdam Gastroenterology Endocrinology & Metabolism, De Boelelaan 1117, Amsterdam 1081 HV, the Netherlands; Endocrine Laboratory, Department of Laboratory Medicine, Amsterdam UMC, Location University of Amsterdam, Amsterdam Reproduction & Development, Meibergdreef 9, Amsterdam 1105 AZ, the Netherlands; Endocrine Laboratory, Department of Laboratory Medicine, Amsterdam UMC, Location Vrije Universiteit Amsterdam, Amsterdam Reproduction & Development, De Boelelaan 1117, Amsterdam 1081 HV, the Netherlands. Electronic address:
Background: An important aspect of the shift towards dried blood spots (DBS) as a sample matrix for laboratory measurements, is the availability of robust liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods that can reliably quantify analyte concentrations in DBS. The development and validation of these LC-MS/MS methods, however, concerns an extensive process, for which large amounts of DBS samples are required. DBS are usually obtained from capillary blood samples, but they can also be prepared from venous (residual) blood samples, which are widely available in clinical laboratories.
View Article and Find Full Text PDFCeram Int
October 2024
Marquette University School of Dentistry, Milwaukee, WI 53233, USA.
Addressing a critical challenge in current tissue-engineering practices, this study aims to enhance vascularization in 3D porous scaffolds by incorporating bioceramics laden with pro-angiogenic ions. Specifically, freeze-dried gelatin-based scaffolds were infused with sol-gel-derived powders of Cu-doped akermanite (CaMgSi2O) and bredigite (CaMgSiO) at various concentrations (10, 20, and 30 wt%). The scaffolds were initially characterized for their structural integrity, biodegradability, swelling behavior, impact on physiological pH, and cytocompatibility with human umbilical vein endothelial cells (HUVECs).
View Article and Find Full Text PDFInt J Legal Med
November 2024
College of Science and Engineering, Flinders University, Bedford Park, South Australia, Australia.
"Shedder status" describes the inherent variation between individuals to leave touch DNA on a surface through direct contact. Depending on the amount and quality of DNA or cellular deposition, individuals are typically deemed high, intermediate, or low shedders. Although many shedder tests have been described, variability in study design and categorisation criteria has limited the ability of researchers to accurately compare results, as well as accrue the necessary population data.
View Article and Find Full Text PDFJ Vector Borne Dis
July 2024
National Institute of Veterinary Epidemiology and Disease Informatics, Yelhanka, Bengaluru, India.
Background Objectives: Theileriosis is an important tick-bome hemoprotozoan disease of cattle which causes severe economic loss due to morbidity and mortality. A diagnostic test having high sensitivity, specificity and easy application at the field level is the need of the hour. In this regard Loop-mediated isothermal amplification (LAMP) is proven to be a sensitive, easy and time efficient method.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!