Objective: This study was performed to investigate the baseline serum titanium levels in patients with short-segment titanium alloy posterior instrumentation and to assess patient-, implant-, and surgery-related factors that might affect the serum titanium level.
Method: Two groups of patients were included in the study. The study group comprised 39 patients who had undergone short-segment posterior instrumentation from January 2013 to June 2016. The control group comprised 11 randomly selected patients who presented to the outpatient clinic with no history of orthopedic surgery. The serum titanium levels and inter-group differences were analyzed.
Results: The mean serum titanium level was significantly higher in the study group than in the control group. No significant difference was observed between patients with different etiologies, implants used for fusion, numbers of instrumented segments, or postoperative durations.
Conclusion: The serum titanium levels of patients with posterior lumbar spinal instrumentation are significantly higher than those of the normal population even after achievement of solid fusion. These levels are not affected by the use of transverse connectors, the use of cages, the operated segments, or the duration of implants.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7829528 | PMC |
http://dx.doi.org/10.1177/0300060520984931 | DOI Listing |
Int J Mol Sci
January 2025
Department of Food Science & Technology, Seoul Women's University, Seoul 01797, Republic of Korea.
Titanium dioxide (TiO), a white color food additive, is widely used in bakery products, candies, chewing gums, soups, and creamers. Concerns about its potential genotoxicity have recently emerged, particularly following the European Union's ban on its usage as a food additive due to its genotoxicity potential. Conflicting in vitro and in vivo results regarding its genotoxicity highlight the need for further in-depth investigation.
View Article and Find Full Text PDFAnal Chim Acta
February 2025
Ministry of Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules, Hubei Key Laboratory for Precision Synthesis of Small Molecule Pharmaceuticals, College of Chemistry and Chemical Engineering, Hubei University, Wuhan, 430062, PR China; Key Laboratory of Advanced Energy Materials Chemistry (Ministry of Education), Nankai University, Tianjin, 300071, PR China. Electronic address:
Background: Traditional lateral flow biosensors (LFBs), which utilize colorimetric signals as output, possess the virtues of simplicity and rapidity. However, it also suffers from insufficient sensitivity and limited reliability. It is well known that the results of LFBs can be false positive, and it is difficult to perform accurate quantification under low-abundance targets.
View Article and Find Full Text PDFJ Clin Med
January 2025
Division of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, 8401 Winterthur, Switzerland.
Wear particle reaction is present in every arthroplasty. Sometimes, this reaction may lead to formation of large pseudotumors. As illustrated in this case, the volume of the reaction may be out of proportion to the volume of the wear scar.
View Article and Find Full Text PDFTalanta
January 2025
Department of Chemistry, Yanbian University, Yanji, 133002, Jilin, China. Electronic address:
Exosomes have emerged as a powerful biomarker for early cancer diagnosis, however, accurately detecting cancer-derived exosomes in biofluids remains a crucial challenge. In this study, we present a novel label-free electrochemical biosensor utilizing titanium dioxide nanotube array films (TiONTAs) for the sensitive detection of exosomes in complex biological samples. This innovative biosensor takes advantage of the excellent electrochemical properties of TiONTAs and their specific interactions with the phosphate groups of exosomes.
View Article and Find Full Text PDFMikrochim Acta
January 2025
Applied Science Department, The NorthCap University, 122017, Gurugram, Haryana, India.
For the first time, a TiCT-MXene and poly (3, 4-ethylenedioxythiophene): poly (styrenesulfonate) (PEDOT: PSS) composite-modified electrode has been developed for electrochemical detection of the bilirubin (BR) by molecularly imprinted ortho-phenylenediamine (o-PD). BR is a biomarker for liver-related diseases. High levels of BR imply liver dysfunction; hence, its exact and rapid measurement is indispensable to its immediate diagnosis and treatment.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!