Objectives: Preoperative estimation of the insertion depth angle of cochlear implant (CI) electrodes is essential for surgical planning. The purpose of this study was to determine the cochlear size using preoperative CT and to investigate the correlation between cochlear size and insertion depth angle in morphologically normal cochlea.
Methods: Thirty-five children who underwent CI were included in this study. Cochlear duct length (CDL) and the diameter of the cochlear basal turn (distance A/B) on preoperative CT and the insertion depth angle of the CI electrode on postoperative radiographs were independently measured by two readers. Correlation between cochlear size and insertion depth angle was evaluated. Interobserver agreement was calculated using the intraclass correlation coefficient (ICC).
Results: The mean CDL, distance A, and distance B of 70 ears were 36.20 ± 1.57 mm, 8.67 ± 0.42 mm, and 5.73 ± 0.32 mm, respectively. The mean insertion depth angle was 431.45 ± 38.42°. Interobserver agreements of CDL, distance A/B, and insertion depth angle were fair to excellent (ICC 0.864, 0.862, 0.529, and 0.958, respectively). Distance A (r = - 0.7643) and distance B (r = - 0.7118) showed a negative correlation with insertion depth angle, respectively (p < 0.0001). However, the correlation between CDL and insertion depth angle was not statistically significant (r = - 0.2333, p > 0.05).
Conclusions: The CDL and cochlear distance can be reliably obtained from preoperative CT. Distance A can be used as a predictive marker for estimating insertion depth angle during CI surgery.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00330-020-07580-4 | DOI Listing |
JAMA Otolaryngol Head Neck Surg
January 2025
Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee.
Importance: Cochlear implants enable improvements in speech perception, but music perception outcomes remain variable. Image-guided cochlear implant programming has emerged as a potential programming strategy for increasing the quality of spectral information delivered through the cochlear implant to improve outcomes.
Objectives: To perform 2 experiments, the first of which modeled the variance in music perception scores as a function of electrode positioning factors, and the second of which evaluated image-guided cochlear implant programming as a strategy to improve music perception with a cochlear implant.
J Cardiothorac Surg
January 2025
Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea.
Background: Several methods for blindly positioning bronchial blockers (BBs) for one-lung ventilation (OLV) have been proposed. However, these methods do not reliably ensure accurate positioning and proper direction. Here, we developed a clinically applicable two-stage maneuver by modifying a previously reported one-stage maneuver for successful insertion of a BB at the appropriate depth and direction in patients requiring lung isolation where a flexible bronchoscope (FOB) is not applicable.
View Article and Find Full Text PDFChem Phys Lipids
January 2025
Laboratory of Molecular Biophysics, Department of Physics, University Jaume I, 12071 Castellón, Spain. Electronic address:
We present an in-depth electrophysiological analysis of Tse5, a pore-forming toxin (PFT) delivered by the type VI secretion system (T6SS) of Pseudomonas aeruginosa. The T6SS is a sophisticated bacterial secretion system that injects toxic effector proteins into competing bacteria or host cells, providing a competitive advantage by disabling other microbes and modulating their environment. Our findings highlight the dependency of Tse5 insertion on membrane charge and electrolyte concentration, suggesting an in vivo effect from the periplasmic space.
View Article and Find Full Text PDFZhongguo Zhen Jiu
January 2025
Department of Acupuncture and Moxibustion, Wuxi Municipal Hospital of TCM, Wuxi 214100, Jiangsu Province, China.
The paper reports one case of osteitis condensans ilii treated with acupuncture in the young and middle-aged female patient. Based on the "analogy" thinking, bilateral Chengshan (BL57) and Ximen (PC4) were selected. The short needling was delivered at Chengshan (BL57), in which, the needle tip went directly to the bone surface and the needle was lifted and thrusted to induce the tolerable sensation.
View Article and Find Full Text PDFJ Conserv Dent Endod
November 2024
Department of Conservative Dentistry and Endodontics, K. M. Shah Dental College and Hospital, Sumandeep Vidyapeeth Deemed to be University, Vadodara, Gujarat, India.
Aim: The aim of the study was to compare and evaluate proximal contact tightness and contours using two newer contact-forming systems in Class II composite restorations.
Materials And Methods: After institutional ethical approval and Clinical Trials Registry-India registration, patients were chosen according to the inclusion-exclusion criteria with informed consent. A total of 60 patients were randomly assigned to two groups.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!