Since the first appearance of the severe acute respiratory syndrome corona virus 2 (SARS-CoV-2) earlier this year, clinicians and researchers alike have been faced with dynamic, daily challenges of recognizing, understanding, and treating the coronavirus disease 2019 (COVID-19) due to SARS-CoV-2. Those who are moderately to severely ill with COVID-19 are likely to develop acute hypoxemic respiratory failure and require administration of supplemental oxygen. Assessing the need to initiate or titrate oxygen therapy is largely dependent on evaluating the patient's existing blood oxygenation status, either by direct arterial blood sampling or by transcutaneous arterial oxygen saturation monitoring, also referred to as pulse oximetry. While the sampling of arterial blood for measurement of dissolved gases provides a direct measurement, it is technically challenging to obtain, is painful to the patient, and can be time and resource intensive. Pulse oximetry allows for non-invasive, real-time, continuous monitoring of the percent of hemoglobin molecules that are saturated with oxygen, and usually closely predicts the arterial oxygen content. As such, it was particularly concerning when patients with severe COVID-19 requiring endotracheal intubation and mechanical ventilation within one of our intensive care units were observed to have significant discordance between their predicted arterial oxygen content via pulse oximetry and their actual measured oxygen content. We offer these preliminary observations along with our speculative causes as a timely, urgent clinical need. In the setting of a COVID-19 intensive care unit, entering a patient room to obtain a fresh arterial blood gas sample not only takes exponentially longer to do given the time required for donning and doffing of personal protective equipment (PPE), it involves the consumption of already sparce PPE, and it increases the risk of viral exposure to the nurse, physician, or respiratory therapist entering the room to obtain the sample. As such, technology similar to pulse oximetry which can be applied to a patients finger, and then continuously monitored from outside the room is essential in preventing a particularly dangerous situation of unrealized hypoxia in this critically-ill patient population. Additionally, it would appear that conventional two-wavelength pulse oximetry may not accurately predict the arterial oxygen content of blood in these patients. This discordance of oxygenation measurements poses a critical concern in the evaluation and management of the acute hypoxemic respiratory failure seen in patients with COVID-19.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7815279 | PMC |
http://dx.doi.org/10.1007/s10439-020-02722-7 | DOI Listing |
Drug Alcohol Depend Rep
March 2025
Institute for Drug and Alcohol Studies, Virginia Commonwealth University, 203 East Cary Street, Richmond, VA 23219, USA.
Background: Evidence supports the common incidence of sleep disturbance in opioid use disorder (OUD) as a potential marker of disrupted orexin system functioning. This study evaluated the initial safety and tolerability of a challenge dose of lemborexant, a dual orexin antagonist, as an adjunct to buprenorphine/naloxone.
Methods: Patients (18-65 years old) with OUD receiving sublingual buprenorphine/naloxone, with a Pittsburgh Sleep Quality Index total score of 6 or higher, were recruited from outpatient clinics.
Fluids Barriers CNS
January 2025
Department of Neurosurgery, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan.
Background: Cerebral autoregulation is a robust regulatory mechanism that stabilizes cerebral blood flow in response to reduced blood pressure, thereby preventing cerebral ischaemia. Scientists have long believed that cerebral autoregulation also stabilizes cerebral blood flow against increases in intracranial pressure, which is another component that determines cerebral perfusion pressure. However, this idea was inconsistent with the complex pathogenesis of normal pressure hydrocephalus, which includes components of chronic cerebral ischaemia due to mild increases in intracranial pressure.
View Article and Find Full Text PDFJ Clin Med
December 2024
Department of Intensive Care, Amsterdam UMC, University of Amsterdam, 1105 AZ Amsterdam, The Netherlands.
: Attaining adequate oxygenation in critically ill patients undergoing invasive ventilation necessitates intense monitoring through pulse oximetry (SpO) and frequent manual adjustments of ventilator settings like the fraction of inspired oxygen (FiO) and the level of positive end-expiratory pressure (PEEP). Our aim was to compare the quality of oxygenation with the use of automated ventilation provided by INTELLiVENT-Adaptive Support Ventilation (ASV) vs. ventilation that is not automated, i.
View Article and Find Full Text PDFSensors (Basel)
January 2025
School of Integrated Health Sciences, Department of Kinesiology and Nutrition Sciences, University of Nevada, Las Vegas, NV 89154, USA.
Introduction: As wearable technology becomes increasingly popular and sophisticated, independent validation is needed to determine its accuracy and potential applications. Therefore, the purpose of this study was to evaluate the accuracy (validity) of VO2max estimates and blood oxygen saturation measured via pulse oximetry using the Garmin fēnix 6 with a general population participant pool.
Methods: We recruited apparently healthy individuals (both active and sedentary) for VO2max (n = 19) and pulse oximetry testing (n = 22).
Sensors (Basel)
December 2024
Biomedicine Research Center of Strasbourg (CRBS), UR 3072, "Mitochondria, Oxidative Stress and Muscle Plasticity", Faculty of Medicine, University of Strasbourg, 67000 Strasbourg, France.
The continuous monitoring of oxygen saturation (SpO) and respiratory rates (RRs) are major clinical issues in many cardio-respiratory diseases and have been of tremendous importance during the COVID-19 pandemic. The early detection of hypoxemia was crucial since it precedes significant complications, and SpO follow-up allowed early hospital discharge in patients needing oxygen therapy. Nevertheless, fingertip devices showed some practical limitations.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!