Sutureless Scleral Fixated IOL: The "Catcher Pole" Technique.

Clin Ophthalmol

La Sapienza University of Rome, Clinica Oculistica Ospedale Umberto I, Rome, Italy.

Published: January 2021

Purpose: To describe a new surgical technique for sutureless intrascleral intraocular lens (IOL) fixation with an adapted retinal scraper used as an instrument "the Catcher Pole" to retrieve the IOL haptic through a scleral tunnel.

Setting: Public Eye Hospital, Roma, Italy.

Design: Retrospective case series.

Methods: Twenty-one eyes from 19 patients who underwent sutureless intrascleral IOL fixation were studied. A standard three-piece posterior chamber IOL (PCIOL) was implanted in aphakia or rescued and fixated in cases of dislocated PCIOL. A 23 to 25 G retinal loop scraper (the "Catcher Pole") was inserted through a 1.5 mm long tunneled sclerotomy performed on the horizontal meridian, to capture, hold and externalize the tip of the haptic of the IOL. A flange created with an handheld cautery on the externalized haptic tip prevents IOL slippage. The best-corrected visual acuity (BCVA), central corneal pachymetry (CCP), IOL tilt and complications were assessed.

Results: In twenty-one eyes of 19 patients, the mean preoperative BCVA was 0.61 logMAR units ±0.05 SD, and the mean postoperative BCVA improved significantly to 0.18 logMAR units at three months ±0.05 SD (=0.002). The mean preoperative CCP was 610 µ ±17 SD and the mean postoperative CCP 623 µ ±16 SD, (=0.73). In the subgroup that underwent IOL tilt evaluation, mean IOL tilt was 3.19±2.01. The postoperative complications included iris capture of the IOL in one eye (4,7%) and transient ocular hypertension in two eyes (9,4%).

Conclusions: The "Catcher Pole" sutureless intrascleral IOL fixation technique is easy to perform with reduced anterior chamber manipulations and achieves both anatomical and optical stability.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7811465PMC
http://dx.doi.org/10.2147/OPTH.S288769DOI Listing

Publication Analysis

Top Keywords

iol
12
"catcher pole"
12
sutureless intrascleral
12
iol fixation
12
iol tilt
12
twenty-one eyes
8
eyes patients
8
intrascleral iol
8
logmar units
8
sutureless
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!