Rotaphone-CY is a six-component short-period seismograph that is capable of the co-located recording of three translational (ground velocity) components along three orthogonal axes and three rotational (rotation rate) components around the three axes in one device. It is a mechanical sensor system utilizing records from elemental sensors (geophones) arranged in parallel pairs to derive differential motions in the pairs. The pairs are attached to a rigid frame that is anchored to the ground. The model design, the latest one among various Rotaphone designs based on the same principle and presented elsewhere, is briefly introduced. The upgrades of the new model are a 32-bit A/D converter, a more precise placing of the geophones to parallel pairs and a better housing, which protects the instrument from external electromagnetic noise. The instrument is still in a developmental stage. It was tested in a field experiment that took place at the Geophysical Observatory in Fürstenfeldbruck (Germany) in November 2019. Four Rotaphones-CY underwent the huddle-testing phase of the experiment as well as the field-deployment phase, in which the instruments were installed in a small-aperture seismic array of a triangular shape. The preliminary results from this active-source experiment are shown. Rotaphone-CY data are verified, in part, by various approaches: mutual comparison of records from four independent Rotaphone-CY instruments, waveform matching according to rotation-to-translation relations, and comparison to array-derived rotations when applicable. The preliminary results are very promising and they suggest the good functionality of the Rotaphone-CY design. It has been proved that the present Rotaphone-CY model is a reliable instrument for measuring short-period seismic rotations of the amplitudes as small as 10-7 rad/s.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7830586PMC
http://dx.doi.org/10.3390/s21020562DOI Listing

Publication Analysis

Top Keywords

model design
8
components three
8
parallel pairs
8
rotaphone-cy
6
rotaphone-cy newest
4
newest rotaphone
4
model
4
rotaphone model
4
design preliminary
4
preliminary performance
4

Similar Publications

The Rey Auditory Verbal Learning Test (RAVLT) is a classic test used to assess episodic verbal memory in research and clinical practice. We aimed to adapt the RAVLT materials into Russian, provide performance norms across the adult lifespan for the Russian adaptation, and develop a mobile application for automated RAVLT administration across languages. We created three psycholinguistically matched alternative versions of the RAVLT materials in Russian and incorporated them into a new tablet application.

View Article and Find Full Text PDF

Introduction: The prevalence of substance use among young adults has been increasing in Turkiye. Probation as a form of execution continues to grow in popularity around the world, as it has the potential for more successful outcomes than closed institutional execution methods. However, in the face of changing societal and individual needs, the probation system must rapidly adapt to current public realities, especially with new approaches, including the use of purposeful physical movement for young adults who are obliged due to illegal substance use.

View Article and Find Full Text PDF

Background: During the COVID-19 pandemia, the imaging test of choice to diagnose COVID-19 pneumonia as chest computed tomography (CT). However, access was limited in the hospital setting and patients treated in Primary Care (PC) could only access the chest x-ray as an imaging test. Several scientific articles that demonstrated the sensitivity of lung ultrasound, being superior to chest x-ray [Cleverley J et al.

View Article and Find Full Text PDF

Monitoring deep wounds is challenging but necessary for high-quality medical treatment. Current methodologies for deep wound monitoring are typically limited to indirect clinical symptoms or costly non-real-time imaging diagnosis. Herein, a smart system is proposed that enables in situ monitoring of deep wounds' status through a semi-implantable device composed of 2 seamlessly connected functional components: 1) the well-designed, microchannel-structured sampling needles that efficiently and conveniently collect samples from deep wound anatomical locations, and 2) the multiplex biochemical testing compartment that facilitates the immediate and persistent detection of multiple biochemical indicators based on a color image processing software accessible to a conventional smartphone.

View Article and Find Full Text PDF

Design of experiments (DOE) is an established method to allocate resources for efficient parameter space exploration. Model based active learning (AL) data sampling strategies have shown potential for further optimization. This paper introduces a workflow for conducting DOE comparative studies using automated machine learning.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!