From September 16, 1981, through April 4, 1986, a total of 21 radiative electromagnetic (microwave and radiofrequency), ultrasound and interstitial radio-frequency hyperthermia applicators and three types of thermometry systems underwent extensive phantom and clinical testing at Stanford University. A total of 996 treatment sessions involving 268 separate treatment fields in 131 patients was performed. Thermal profiles were obtained in 847 of these treatment sessions by multipoint and/or mapping techniques involving mechanical translation. The ability of these devices to heat superficial, eccentrically located and deep-seated tumours at the major anatomical locations is evaluated and the temperature distributions, acute and subacute toxicities, and chronic complications compared. Average measured tumour temperatures between 42 degrees C and 43 degrees C were obtained with many of the devices used for superficial heating; average tumour temperatures of 39.6 degrees C to 42.1 degrees C were achieved with the three deep-heating devices. When compared to the goal of obtaining minimum tumour temperatures of 43.0 degrees C, all devices performed poorly. Only 14 per cent (118/847) of treatments with measured thermal profiles achieved minimum intratumoural temperatures of 41 degrees C. Fifty-six per cent of all treatments had associated acute toxicity; 14 per cent of all treatments necessitated power reduction resulting in maximum steady-state temperatures of less than 42.5 degrees C. Direct comparisons between two or more devices utilized to treat the same field were made in 67 instances, including 19 treatment fields in which two or more devices were compared at the same treatment session. The analyses from direct comparisons consistently showed that the static spiral and larger area scanning spiral applicators resulted in more favourable temperature distributions. Three fibreoptic thermometry systems (Luxtron single channel, four channel and eight channel multiple [four] probe array), the BSD Bowman thermistor system and a thermocouple system were evaluated with respect to accuracy, stability and artifacts. The clinical reliability, durability, and patient tolerance of the thermometry systems were investigated. The BSD Bowman and third generation Luxtron systems were found clinically useful, with the former meeting all of our established criteria.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3109/02656738809032050 | DOI Listing |
Int J Mol Sci
December 2024
Department of Physical Therapy, Faculty of Health Sciences, University of Granada (UGR), 18071 Granada, Spain.
The aim of this study was to analyze the association between circulating amino acids and central and peripheral body temperature in subjects with and without fibromyalgia syndrome (FMS). A total of 47 patients with FMS and 59 healthy subjects were included in the study. The concentration of amino acids was determined in serum samples using a fluorimeter coupled with a high-performance liquid chromatography system.
View Article and Find Full Text PDFDalton Trans
January 2025
Department of Physics, University of Kerala, Kariavattom Campus, Thiruvananthapuram, Kerala - 695 581, India.
Tuning the photophysical response is indispensable in realizing the full potential of phosphors to meet the demands of multifunctional applications, such as solid-state lighting and optical thermometry. Herein, orange-red emission from an Sm-based LiYTeO system was studied for the first time with CIE coordinates of (0.488, 0.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA.
This paper describes the design and initial proof-of-concept of a single pre-clinical transcranial focused ultrasound (FUS) system capable of performing histotripsy (mechanical ablation), hyperthermia, blood-brain barrier opening (BBBO), sonodynamic therapy, or neuromodulation in a murine brain. We have termed it the All-in-One FUS system for murine brain studies, which is the first FUS system of its kind. The 1.
View Article and Find Full Text PDFJ Chem Phys
December 2024
Deep Space Exploration Laboratory/Department of Modern Mechanics, University of Science and Technology of China, Hefei 230026, People's Republic of China.
This paper performed a comprehensive study of the thermal nonequilibrium effects of CO/Ar mixtures with various degrees of N2 additions and probed the N2 relaxation behaviors via the CO rovibrational thermometry. The rovibrational temperature time histories of shock-heated CO/N2/Ar mixtures were measured via a laser-absorption technique, and the corresponding vibrational relaxation data were summarized at 1890-3490 K. The measured results were compared with predictions from the Schwartz-Slawsky-Herzfeld (SSH) formula and the state-to-state (StS) approach (treating CO and N2 as pseudo-species).
View Article and Find Full Text PDFBeijing Da Xue Xue Bao Yi Xue Ban
December 2024
Department of Rheumatology and Immunology, Beijing Hospital; National Center of Gerontology; Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing 100730, China.
Infrared thermography is an advanced technology that utilizes infrared detectors to sense the infrared thermal radiation emitted from the human body' s surface, converting it into electrical signals. These signals are then processed by computers to generate planar temperature color images, providing an intuitive display of the body surface temperature distribution. Rheumatic diseases, as prevalent conditions that significantly impact the quality of life of millions of people worldwide, pose significant challenges in diagnosis and assessment.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!