A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Short Communication: Evaluation of Antiretroviral Drug Concentrations in Minimally Invasive Specimens for Potential Development of Point-of-Care Drug Assays. | LitMetric

Point-of-care (POC) tests for antiretroviral drugs (ARVs) could help improve individual adherence. This study sought to define the utility of urine, blood, and buccal swabs as minimally invasive specimens amenable to development of POC tests for ARVs. Urine, dried blood spots (DBS) and buccal swabs were collected from 35 HIV-negative men between 2 and 96 h after a single dose of tenofovir (TFV) alafenamide/emtricitabine (FTC)/elvitegravir (EVG)/cobicistat and darunavir (DRV). ARV concentrations were measured by high-performance liquid chromatography-mass spectrometry. High concentrations of FTC, DRV, and TFV were detectable in urine at least 24 h after dosing. FTC, DRV, and EVG remained detectable in DBS at least 24 h postdose. FTC and DRV were detectable on buccal swabs up to 2 and 24 h postdose, respectively. TFV was not detectable in DBS or buccal swabs collected between 2 and 96 h after dosing. Variable distribution of ARVs in minimally invasive specimens highlights the challenge of developing POC assays for recent ARV exposure.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10134740PMC
http://dx.doi.org/10.1089/AID.2020.0187DOI Listing

Publication Analysis

Top Keywords

buccal swabs
16
minimally invasive
12
invasive specimens
12
ftc drv
12
poc tests
8
dbs buccal
8
swabs collected
8
tfv detectable
8
detectable dbs
8
24 h postdose
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!