Contact line relaxation of sessile drops on PDMS surfaces: A methodological perspective.

J Colloid Interface Sci

Laboratory of Surface and Interface Physics, Department of Applied Physics, University of Granada, Campus de Fuentenueva, ES-18071 Granada, Spain. Electronic address:

Published: May 2021

Hypothesis: Characterization of contact angle hysteresis on soft surfaces is sensitive to the measurement protocol and might present adventitious time-dependencies. Contact line dynamics on solid surfaces is altered by the surface chemistry, surface roughness and/or surface elasticity. We observed a "slow" spontaneous relaxation of static water sessile drops placed on elastic surfaces. This unexpected drop motion reveals unresolved equilibrium configurations that may affect the observed values of contact angle hysteresis. Drop relaxation on deformable surfaces is partially governed by a viscoelastic dissipation located at the contact line.

Experiments: In this work, we studied the natural relaxation of water drops formed on several smooth PDMS surfaces with different elastic moduli. We monitored in time the contact angle and contact radius of each drop. For varying the initial contact angle, we used the growing-shrinking drop method.

Findings: We postulate that the so-called "braking effect", produced by the surface deformability, affects the contact line velocity and in consequence, the contact angle measurements. We conclude that the wetting properties of elastic surfaces should be properly examined with reliable values of contact angle measured after drop relaxation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcis.2020.12.093DOI Listing

Publication Analysis

Top Keywords

contact angle
24
contact
11
sessile drops
8
pdms surfaces
8
angle hysteresis
8
elastic surfaces
8
values contact
8
drop relaxation
8
surfaces
7
angle
6

Similar Publications

Mapping the myomagnetic field of a straight and easily accessible muscle after electrical stimulation using triaxial optically pumped magnetometers (OPMs) to assess potential benefits for magnetomyography (MMG). Approach: Six triaxial OPMs were arranged in two rows with three sensors each along the abductor digiti minimi (ADM) muscle. The upper row of sensors was inclined by 45° with respect to the lower row and all sensors were aligned closely to the skin surface without direct contact.

View Article and Find Full Text PDF

Catechol-derived polymers form stable coatings on a wide range of materials including challenging to coat low surface energy polymers. Whether modification of the coating polymer with fluorophilic or hydrophobic groups is a successful approach to further favor the coating of hydrophobic or fluorophilic surfaces with catechol-based polymers remains ambiguous. Herein, we report the effect of a series of catechol-derived polyglycerol (PG)-based coatings and monolayer coatings on the wettability of polytetrafluoroethylene (PTFE), polystyrene, and poly(methyl methacrylate) surfaces.

View Article and Find Full Text PDF

High performance humidity sensor based on a graphene oxide-chitosan composite.

Phys Chem Chem Phys

January 2025

Temperature and Humidity Metrology, CSIR-National Physical Laboratory, Dr K. S. Krishnan Marg, New Delhi, 110012, India.

In this study, we have proposed an advanced humidity sensor based on a composite of chitosan (CS) and graphene oxide (GO), prepared by the drop casting method. Graphene oxide-chitosan (GO-CS) films with varying volumetric ratios, along with pure GO and CS films, were prepared and extensively characterized using XRD, Raman, FTIR, SEM, XPS, and water contact angle to study their structural and morphological properties. Comparative analysis of humidity sensing parameters of all prepared films revealed that the film with a volumetric ratio of 4 : 1 (GOCS-2) performs best among all of them, which is attributed to the synergistic interaction between GO and CS.

View Article and Find Full Text PDF

Dual-sided centripetal microgrooved poly (D,L-lactide-co-caprolactone) disk encased in immune-regulating hydrogels for enhanced bone regeneration.

Mater Today Bio

February 2025

China Uruguay Bio-Nano Pharmaceutical Joint Laboratory, Institute of Neuroregeneration and Neurorehabilitation, Qingdao University, 308 Ningxia Road, Qingdao, 266071, Shandong, China.

Well-designed artificial scaffolds are urgently needed due to the limited self-repair capacity of bone, which hampers effective regeneration in critical defects. Optimal scaffolds must provide physical guidance to recruit cells and immune regulation to improve the regenerative microenvironment. This study presents a novel scaffold composed of dual-sided centripetal microgrooved poly(D,L-lactide-co-caprolactone) (PLCL) film combined with a dynamic hydrogel containing prednisolone (PLS)-loaded Prussian blue nanoparticles (PB@PLS).

View Article and Find Full Text PDF

Background: Osoto-gari is a leg throw technique that primarily relies on the hip extension to initiate the sweeping motion of the leg. A high sweep contact velocity is a crucial factor in efficiently executing this technique. While some literature emphasises whole-body coordination in the leg-sweeping action, the roles of trunk and head motion remain unclear.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!