This study assesses the extraction of eleven pharmaceuticals, five pesticides, five perfluoroalkyl substances, and two illicit drugs in hemolymph from (Mytilus Galloprovincialis). Four extraction procedures using Phree™ Phospholipid Removal cartridges were tested using different volumes of methanol (400 and 600 μL) and acetonitrile (300 and 450 μL). The pollutants were determined by high-performance liquid chromatography-tandem mass spectrometry. The use of methanol gave several problems during the extraction procedure, such as longer times and sample loss. Three methods (acetonitrile 300 and 450 μL; and methanol 600 μL) were validated. Recoveries at three concentration levels (5, 50, and 100 ng/mL) ranged 35.1-129.0 and 29.3-133.0% for acetonitrile 300 and 450 μL, respectively, while recoveries for methanol 600 μL ranged 52.2-166.0%. Limits of detection were < 10 ng/mL for most analytes using any of the methods. Methanol 600 μL was the only method capable to extract the illicit drug 4-methoxyphencyclidine and provided a better peak shape and higher signal-noise ratio. When applied to non-spiked samples from local markets salicylic acid and diclofenac were detected at 33.50-97.79 and 28.30-30.31 ng/mL respectively. To our knowledge, there are no methods to determine organic contaminants in hemolymph and this is the first application of Phree™ cartridges for mussel hemolymph extraction.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jssc.202001211 | DOI Listing |
Luminescence
January 2025
Department of Chemistry, School of Advanced Engineering, UPES Dehradun, Dehradun, Uttarakhand, India.
Anions play a crucial role in various environmental, chemical, and biological processes. Among various anions, the production of perchlorate (ClO ) ion is expected to rise in upcoming years, and thus, an efficient method for the detection of perchlorate ion is highly desirable. In this effort, a pyridyl-benzimidazole-based luminescent probe (RSB1) containing two N-H donor sites has been synthesized for selective detection of perchlorate ion.
View Article and Find Full Text PDFAm J Transl Res
December 2024
Department of Pharmacy, The Fourth Hospital of Hebei Medical University Shijiazhuang 050000, Hebei, China.
Objectives: The aim of this study was to establish an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the detection of osimertinib in rat plasma, lung and brain tissues.
Methods: Forty-eight rats were randomly divided into an experimental group (receiving osimertinib at doses of 5, 8, and 10 mg/kg) and a control group. After continuous intragastric administration for 15 days, samples of blood, lung, and brain tissue were collected.
Sci Rep
January 2025
Egyptian Drug Authority (EDA), Giza, 35521, Egypt.
J Org Chem
December 2024
Department of Chemistry & Frontier Research Center on Fundamental and Applied Sciences of Matters, National Tsing Hua University, Hsinchu 300, Taiwan.
A synthetic method was developed for the generation of a quaternary carbon center in carbonyl compounds. This innovative process involved the reaction of α-thiolate lactones and cycloalkanones with two equivalents of arynes in acetonitrile to give α,α-diarylated products in 63-85% yields at 25 °C. The reaction unfolds through an unconventional domino process, encompassing sequential 1,2-elimination, 1,2-nucleophilic addition, 1,4-proton transfer, the second 1,2-nucleophilic addition, interrupted Pummerer rearrangement, intramolecular spirocyclization, and sulfonium ring-opening.
View Article and Find Full Text PDFClin Chim Acta
January 2025
Federal University of Rio de Janeiro - UFRJ, Brazilian Doping Control Laboratory - LBCD, LADETEC, Av. Horácio Macedo, 1281 - Polo de Química - Bloco C - Cidade Universitária - Ιlha do Fundão, Rio de Janeiro, Brazil.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!