Introduction: Studies have suggested that optically stimulated luminescent dosimeters (OSLDs) can be used for dosimetry of intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT). Clinical uncertainties such as placement error have not been thoroughly investigated. The purpose of this work was to measure OSLD placement error in a clinical sample and analyze its dosimetric impact.

Methods And Materials: The analysis consisted of three parts: first, quantification of placement error in a clinical sample of 128 patients yielding 293 cone-beam CT (CBCT) with visible OSLDs registered to the treatment plan; Second, correlation of placement error and clinical OSLD measurements; third, simulation of dosimeter placement in the treatment plan and correlation of recalculated dose with placement error.

Results: In the first analysis, average placement error was 9.7 ± 9.5 mm. In the second analysis, placement error and measured-to-planned dose agreement yielded no correlation (R = 0.02) for a subsample of 77 CBCTs of 55 head-and-neck patients. Average placement error was 7.0 ± 6.0 mm. Several factors, including image-guided shifts, introduced uncharacterized uncertainty to the measured-to-planned dose agreement. The third analysis isolated placement error from these other effects. Average dosimetric error was -2.4 ± 19.3%. Simulated dosimetric impact was weakly correlated with placement error (R = 0.39). Removing outliers reduced the average dosimetric error to -2.1 ± 10.9%, marginally improving the correlation (R = 0.44).

Conclusion: Placement error can substantially impact measured-to-planned dose agreement of OSLDs in high gradient regions, demonstrating the criticality of accurate dosimeter placement for IMRT and VMAT treatments.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7807655PMC
http://dx.doi.org/10.1016/j.phro.2019.08.004DOI Listing

Publication Analysis

Top Keywords

placement error
40
placement
14
error
12
error clinical
12
measured-to-planned dose
12
dose agreement
12
dosimetric impact
8
optically stimulated
8
stimulated luminescent
8
clinical sample
8

Similar Publications

A prediction method and evaluation for assessing guide-supported dental implant accuracy.

Comput Methods Biomech Biomed Engin

February 2025

Zhejiang Weilian Technology Co., Ltd, Jiaxing, China.

Functional and esthetic results require accurate implant placement. We aimed to develop a predictive method for assessing dental implant accuracy, and to evaluate the cumulative system influence of surgical guides. A mathematical model was constructed to determine the influence of surface changes on a specific point, using Jacobian matrix expressions.

View Article and Find Full Text PDF

Low-cost male urogenital simulator for penile implant surgery training: a 3D printing approach.

3D Print Med

January 2025

Department of Surgical & Interventional Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.

Background: Penile implant surgery is the standard surgical treatment for end-stage erectile dysfunction. However, the growing complexity of modern high-tech penile prostheses has increased the demand for more practical training opportunities. The most advanced contemporary training methods involve simulation training using cadavers, with costs exceeding $5,000 per cadaver, inclusive of biohazard fees.

View Article and Find Full Text PDF

Robot calibration and modelling measurements are commonly performed using a laser tracker. To capture three-dimensional positions, a SMR is attached to the robot. While some researchers employ adhesive bonds for this purpose, such methods often result in inaccurate, unstable and non-repeatable SMR positioning, adversely affecting measurement precision and the traceability of research outcomes.

View Article and Find Full Text PDF

Accuracy of Rhythm Diagnostic Systems' MultiSense in Detection of Arterial Oxygen Saturation and Respiratory Rate During Hypoxia in Humans: Effects of Skin Color and Device Localization.

Sensors (Basel)

December 2024

Biomedicine Research Center of Strasbourg (CRBS), UR 3072, "Mitochondria, Oxidative Stress and Muscle Plasticity", Faculty of Medicine, University of Strasbourg, 67000 Strasbourg, France.

The continuous monitoring of oxygen saturation (SpO) and respiratory rates (RRs) are major clinical issues in many cardio-respiratory diseases and have been of tremendous importance during the COVID-19 pandemic. The early detection of hypoxemia was crucial since it precedes significant complications, and SpO follow-up allowed early hospital discharge in patients needing oxygen therapy. Nevertheless, fingertip devices showed some practical limitations.

View Article and Find Full Text PDF

This work introduces a novel methodology for identifying critical sensor locations and detecting defects in structural components. Initially, a hybrid method is proposed to determine optimal sensor placements by integrating results from both the discrete empirical interpolation method (DEIM) and the random permutation features importance technique (PI). Subsequently, the identified sensors are utilized in a novel defect detection approach, leveraging a semi-intrusive reduced order modeling and genetic search algorithm for fast and reliable defect detection.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!