Osteolysis and aseptic loosening due to wear at the articulating interfaces of prosthetic joints are considered to be the key concerns for implant failure in load-bearing orthopedic applications. In an effort to reduce the wear and processing difficulties of ultrahigh-molecular-weight polyethylene (UHMWPE), our research group recently developed high-density polyethylene (HDPE)/UHMWPE nanocomposites with chemically modified graphene oxide (mGO). Considering the importance of sterilization, this work explores the influence of γ-ray dosage of 25 kGy on the clinically relevant performance-limiting properties of these newly developed hybrid nanocomposites in vitro. Importantly, this work also probes into the cytotoxic effects of the wear debris of different compositions and sizes on MC3T3 murine osteoblasts and human mesenchymal stem cells (hMSCs). In particular, γ-ray-sterilized 1 wt % mGO-reinforced HDPE/UHMWPE nanocomposites exhibit an improvement in the oxidation index (16%), free energy of immersion (-12.1 mN/m), surface polarity (5.0%), and hardness (42%). Consequently, such enhancements result in better tribological properties, especially coefficient of friction (+13%) and wear resistance, when compared with UHMWPE. A spectrum of analyses using transmission electron microscopy (TEM) and in vitro cytocompatibility assessment demonstrate that phagocytosable (0.5-4.5 μm) sterilized 1 mGO wear particles, when present in culture media at 5 mg/mL concentration, induce neither significant reduction in MC3T3 murine osteoblast and hMSC growth nor cell morphology phenotype, during 24, 48, and 72 h of incubation. Taken together, this study suggests that γ-ray-sterilized HDPE/UHMWPE/mGO nanocomposites can be utilized as promising articulating surfaces for total joint replacements.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsbiomaterials.9b01327DOI Listing

Publication Analysis

Top Keywords

hdpe/uhmwpe nanocomposites
12
wear resistance
8
chemically modified
8
wear debris
8
mc3t3 murine
8
wear
7
nanocomposites
5
probing influence
4
influence γ-sterilization
4
γ-sterilization oxidation
4

Similar Publications

Ultra-high molecular weight polyethylene (UHMWPE) and its derivatives have been clinically used as an acetabular liner material in total hip joint replacement (THR) over last six decades. Despite significant efforts, the longevity of UHMWPE implants is still impaired due to their compromised tribological performance, leading to osteolysis and aseptic loosening. The present study aims to critically evaluate and analyze the tribological performance, of the next generation acetabular liner material, that is, a chemically modified graphene oxide (GO) reinforced HDPE/UHMWPE (HU) bionanocomposite (HUmGO), against stainless steel (SS 316L) counterface in lubricated conditions.

View Article and Find Full Text PDF

Osteolysis and aseptic loosening due to wear at the articulating interfaces of prosthetic joints are considered to be the key concerns for implant failure in load-bearing orthopedic applications. In an effort to reduce the wear and processing difficulties of ultrahigh-molecular-weight polyethylene (UHMWPE), our research group recently developed high-density polyethylene (HDPE)/UHMWPE nanocomposites with chemically modified graphene oxide (mGO). Considering the importance of sterilization, this work explores the influence of γ-ray dosage of 25 kGy on the clinically relevant performance-limiting properties of these newly developed hybrid nanocomposites in vitro.

View Article and Find Full Text PDF

High-density polyethylene (HDPE)-based and ultra-high molecular weight polyethylene (UHMWPE)-based composites with carbonaceous reinforcements are being widely investigated for biomedical applications. The enhancement of material properties critically depends on the nature, amount and compatibility of the reinforcement with the polymeric matrix. To this end, this study demonstrates the efficacy of a 'dual' hybrid approach of incorporating modified inorganic nanofiller into an optimized polyethylene blend.

View Article and Find Full Text PDF

Biocompatibility of β-TCP/HDPE-UHMWPE nanocomposite as a new bone substitute material was evaluated by using highly purified human osteoblast cells. Human osteoblast cells were isolated from bone tissue and characterized by immunofluorescence Staining before and after purification using magnetic bead system. Moreover, proliferation, alkaline phosphatase production, cell attachment, calcium deposition, gene expression, and morphology of osteoblast cells on β-TCP/HDPE-UHMWPE nanocomposites were evaluated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!