Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Phospholipase-A (PLA) enzymes catalyze the hydrolysis of ester bonds in select glycerophospholipids. Sensors for rapidly measuring the PLA activity in biological samples have relevance in the study of venom compositions and in medical diagnostics for the diagnosis of diseases such as acute pancreatitis. Current PLA sensor technologies are often restricted by the time it takes to prepare an assay, the necessity of using fluorescent labels, or the fact they might require strict pH control of the buffer vehicles used. Here we present a tethered bilayer lipid membrane (tBLM) impedance sensor array for the rapid and real-time detection of PLA, which includes the ability to selectively detect phospholipase-A (PLA) from phospholipase-A (PLA) isoforms. Comparing the activity of PLA and PLA in an array of tBLMs composed of ether phospholipids, ester phospholipids or ether-ester phospholipids allows for the rapid and reliable distinction between the isoforms, as measured using swept-frequency electrical impedance spectroscopy. After testing the assay using pure enzymes, we demonstrate the capacity of the sensor to identify specific PLA-type, calcium-dependent activity from the venom of the South American bullet ant, , at a concentration of 1 μg/mL. The specificity of the phospholipase activity was corroborated using matrix-assisted laser-desorption/ionization time-of-flight mass spectrometry. As further validation, we tested the activities of a PLA isoform in the presence of different buffers commonly used in biology and biochemistry experiments. Sensitivity testing shows that PLA can be detected at an activity as low as 0.06 U/mL. The rapid and reliable detection of phospholipases presented in this study has potential applications in the study of animal venoms as well as in lipase bioreactors and point-of-care devices.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acsbiomaterials.0c00632 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!