Ultrasound probe tilt impedes the needle-beam alignment during the ultrasound-guided procedures.

Sci Rep

Department of Anesthesiology, Daping Hospital, Army Medical University, 10 ChangjiangZhilu, Yuzhong District, Chongqing, 400042, China.

Published: January 2021

The objective of this study was to identify the factors that complicate the needle visualization in ultrasound-guided in-plane needling procedures. Forty-nine residents were recruited and randomized to insert the simulated blood vessel with four different views including Neutral (the long axis of the probe along the visual axis and the ultrasonic beam vertical to the surface of gel phantom), 45°-rotation (45° angle between the long axis of probe and the operator's visual axis), 45°-tilt (45° angle between the ultrasonic beam and the surface of gel phantom) and 45°-rotation plus 45°-tilt of probe. Number of needle redirections, insertion time, and needle visibility were documented and compared for each procedure. When the residents faced with 45°-tilt view, the needle redirections (2 vs 0) and insertion time increased significantly (39 vs 16) compared with that of the Neutral view. When faced with 45°-rotation plus 45°-tilt view, the residents' performance decreased further as compared with that of the 45°-tilt view and the Neutral view. However, there was no performance difference between the Neutral view and 45°-rotation view. In conclusion, during ultrasound-guided in-plane procedures, tilting the ultrasound probe may increase the difficulty of needle-beam alignment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7810715PMC
http://dx.doi.org/10.1038/s41598-021-81354-wDOI Listing

Publication Analysis

Top Keywords

45°-tilt view
12
neutral view
12
ultrasound probe
8
needle-beam alignment
8
ultrasound-guided in-plane
8
long axis
8
axis probe
8
visual axis
8
ultrasonic beam
8
surface gel
8

Similar Publications

. The released CMRxRecon2024 dataset is currently the largest and most protocol-diverse publicly available k-space dataset including multi-modality and multi-view cardiac MRI data from 330 healthy volunteers, and each one covers standardized and commonly used clinical protocols. ©RSNA, 2025.

View Article and Find Full Text PDF

Ocular injuries by less-lethal weapon: a view from Switzerland.

Torture

January 2025

MD. Private practice, Zurich, Switzerland. Correspondence to

Dear Editor-in-chief: Thank you for focussing on this troubling subject in your issue 1/2024. It confirms that many of the difficulties involved are similar worldwide. Countries that use less-lethal weapons include Switzerland, the only Western European democracy besides France to employ multiple kinetic impact projectiles.

View Article and Find Full Text PDF

Telomemore enables single-cell analysis of cell cycle and chromatin condensation.

Nucleic Acids Res

January 2025

Laboratory for Molecular Infection Medicine Sweden (MIMS), Umeå University, Biomedicinbyggnaden 6K och 6L, Umeå universitetssjukhus, 901 87, Umeå, Sweden.

Single-cell RNA-seq methods can be used to delineate cell types and states at unprecedented resolution but do little to explain why certain genes are expressed. Single-cell ATAC-seq and multiome (ATAC + RNA) have emerged to give a complementary view of the cell state. It is however unclear what additional information can be extracted from ATAC-seq data besides transcription factor binding sites.

View Article and Find Full Text PDF

Three-Dimensional CT for Preprocedural Planning of PCI for Ostial Right Coronary Artery Lesions: A Randomized Controlled Pilot Trial.

Circ Cardiovasc Interv

January 2025

Department of Cardiology, Ziekenhuis Oost-Limburg, Genk, Belgium (D.M.F.v.d.B., E.M.P., E.W., D.C., E.M., B.F., M.V., J.D., K.A.).

Background: Geographic stent-ostium mismatch is an important predictor of target lesion failure after percutaneous coronary intervention of an aorto-ostial right coronary artery lesion. Optimal visualization of the aorto-ostial plane is crucial for precise stent implantation at the level of the ostium. This study investigates whether preprocedural 3-dimensional computed tomography (3DCT), with determination of the optimal viewing angle, would allow for more precise stent implantation and reduce procedure time, contrast, and radiation dose.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!