Effect of Porous Microstructures on the Biomechanical Characteristics of a Root Analogue Implant: An Animal Study and a Finite Element Analysis.

ACS Biomater Sci Eng

Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing 400010, China.

Published: November 2020

Background: Full ceramic or metal custom-made root analogue implants (RAIs) are made by replicating the natural tooth geometry. However, it may lead to the stress shielding of the surrounding bone, and an RAI is unable to easily achieve primary stability. Therefore, to improve primary stability and reduce stress shielding, RAI porous structures are proposed. The purpose of this study was to evaluate the effect of porous microstructures on the biomechanical characteristics of the custom-made RAI.

Methods: Porous and bulk titanium cylinders and porous RAI and conventional implants for in vivo tests were fabricated using a selective laser melting (SLM) technology. The elastic modulus and the compressive strength of porous titanium cylinders were evaluated. These samples were then implanted into rabbit femurs (cylinders) and beagle dog mandibles (RAI and conventional implants). A simplified three-dimensional geometry of the anterior maxilla of a patient was constructed. Then, based on the extracted standard template library (STL) data, five different RAI models were constructed: (A) smooth surface, (B) pit surface, (C) bulb surface, (D) threaded surface, and (E) porous surface. A conventional implant model was also constructed. A static load of 100 N was applied to the crown in the multivectoral direction.

Results: The results of the in vivo experiment confirmed that the porous structure decreased the elastic modulus of Ti6Al4V. Additionally, the implantation of the porous custom-made RAIs resulted in increased new bone ingrowth and decreased bone resorption compared to conventional implants. Moreover, the 3D finite element analysis suggested that the bone surrounding porous custom-made RAIs was subjected to a more uniform stress distribution, and the strain values of the surrounding bone were more conducive to bone formation.

Conclusion: Based on these findings, a custom-made RAI with a porous surface accelerates bone formation and might reduce the stress-shielding effect.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsbiomaterials.0c01096DOI Listing

Publication Analysis

Top Keywords

conventional implants
12
porous
11
porous microstructures
8
microstructures biomechanical
8
biomechanical characteristics
8
root analogue
8
finite element
8
element analysis
8
stress shielding
8
surrounding bone
8

Similar Publications

Dynamic Navigation in Dental Implantology.

Discoveries (Craiova)

December 2023

Periodontics Division, Department of Dentistry, All India Institute of Medical Sciences, Bathinda, Punjab, India.

Implant placement for dental rehabilitation has gained more popularity among patients in the recent past. Dental Implants are the workhorse of dentistry. Previously, the implants were placed with the help of the traditional freehand approach.

View Article and Find Full Text PDF

Stereotactic systems have traditionally used Cartesian coordinate combined with linear algebraic mathematical models to navigate the brain. Previously, the development of a novel stereotactic system allowed for improved patient comfort, reduced size, and carried through a simplified interface for surgeons. The system was designed with a work envelope and trajectory range optimized for deep brain stimulation applications only.

View Article and Find Full Text PDF

Faster Acquisition and Improved Image Quality of T2-Weighted Dixon Breast MRI at 3T Using Deep Learning: A Prospective Study.

Korean J Radiol

January 2025

Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.

Objective: The aim of this study was to compare image quality features and lesion characteristics between a faster deep learning (DL) reconstructed T2-weighted (T2-w) fast spin-echo (FSE) Dixon sequence with super-resolution (T2) and a conventional T2-w FSE Dixon sequence (T2) for breast magnetic resonance imaging (MRI).

Materials And Methods: This prospective study was conducted between November 2022 and April 2023 using a 3T scanner. Both T2 and T2 sequences were acquired for each patient.

View Article and Find Full Text PDF

Background: Cochlear implants (CIs) are neuroprosthetic devices which restore hearing in severe-to-profound hearing loss through electrical stimulation of the auditory nerve. Current CIs use an externally worn audio processor. A long-term goal in the field has been to develop a device in which all components are contained within a single implant.

View Article and Find Full Text PDF

Introduction And Aims: Implantation of the posterior maxilla with insufficient bone height faces challenges. Studies have shown that the use of ultrashort implants can avoid additional damage. This finite element analysis study aimed to evaluate the impacts of different lengths of ultrashort implants and three surgical approaches on stress, strain, and displacement in the posterior maxilla with varying bone heights.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!