A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Synthetic polymer hydrogels as potential tissue phantoms in radiation therapy and dosimetry. | LitMetric

Synthetic polymer hydrogels as potential tissue phantoms in radiation therapy and dosimetry.

Biomed Phys Eng Express

Department of Physics and Electronics, CHRIST (Deemed to be University), Bangalore Central Campus, Bengaluru - 560029, Karnataka, India.

Published: July 2020

The efficacy of synthetic polymers as hydrogel phantoms for radiation therapy and dosimetry has been investigated for photon and charged particle (electron, proton and alpha particle) interactions. Tissue equivalence has been studied in terms of photon mass energy-absorption coefficients, KERMA (kinetic energy released per unit mass), equivalent atomic number and energy absorption build-up factors, relative to human tissues (skin, soft tissue, cortical bone and skeletal muscle), in the energy range 0.015-15 MeV. For charged particle interactions, ratio of effective atomic number is examined for tissue-equivalence in the energy region of 10 keV-1 GeV. Well established theoretical formulations are used for computation of photon mass-energy absorption effective atomic number, electron density and KERMA. Five-parameter geometric progression (G-P) fitting approximation is used to compute the values of energy absorption build-up factors. Effective atomic number for charged particle interaction is determined using logarithmic interpolation method. Using the analytical methodology, it has been revealed that all the selected synthetic polymers have good tissue-equivalence relative to all tissue except cortical bone. In particular, polyglycolic acid (PGA) and poly-lactic-co-glycolic acid (PLGA) prove to be best substitute material for photon interactions. On the other hand, % difference between effective atomic number for charged particle relative to human tissues is found least for polyethylene glycol (PEG) demonstrating adequate tissue-equivalence. Therefore, the present study is expected to be useful to choose most appropriate phantom material for radiation therapy.

Download full-text PDF

Source
http://dx.doi.org/10.1088/2057-1976/aba209DOI Listing

Publication Analysis

Top Keywords

atomic number
20
charged particle
16
effective atomic
16
radiation therapy
12
phantoms radiation
8
therapy dosimetry
8
synthetic polymers
8
particle interactions
8
energy absorption
8
absorption build-up
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!