Visual Acuity Testing for Telehealth Using Mobile Applications.

JAMA Ophthalmol

Department of Ophthalmology and Visual Sciences, Yale School of Medicine, New Haven, Connecticut.

Published: March 2021

Importance: The coronavirus disease 2019 pandemic illustrates the increasingly important role of telemedicine as a method of clinician-patient interaction. However, electronic applications (apps) for the testing of ophthalmology vital signs, such as visual acuity, can be published and used without any verification of accuracy, validity, or reliability.

Objective: To reassess the accuracy of visual acuity-testing apps and assess their viability for telehealth.

Design, Setting, And Participants: The US Apple App Store was queried for apps for visual acuity testing. Anticipated optotype size for various visual acuity lines were calculated and compared against the actual measured optotype size on 4 different Apple hardware devices. No human participants were part of this study.

Main Outcomes And Measures: Mean (SD) errors were calculated per device and across multiple devices.

Results: On iPhones, 10 apps met inclusion criteria, with mean errors ranging from 0.2% to 109.9%. On the iPads, 9 apps met inclusion criteria, with mean errors ranging from 0.2% to 398.1%. Six apps met criteria and worked on both iPhone and iPad, with mean errors from 0.2% to 249.5%. Of the 6 apps that worked across devices, the top 3 most accurate apps were Visual Acuity Charts (mean [SD] error, 0.2% [0.0%]), Kay iSight Test Professional (mean [SD] error, 3.5% [0.7%]), and Smart Optometry (mean [SD] error, 15.9% [4.3%]). None of the apps tested were ideal for telemedicine, because some apps displayed accurate optotype size, while others displayed the same letters on separate devices; no apps exhibited both characteristics.

Conclusions And Relevance: Both Visual Acuity Charts and Kay iSight Test Professional had low mean (SD) errors and functionality across all tested devices, but no apps were suitable for telemedicine. This suggests that new and/or improved visual acuity-testing apps are necessary for optimal telemedicine use.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7809609PMC
http://dx.doi.org/10.1001/jamaophthalmol.2020.6177DOI Listing

Publication Analysis

Top Keywords

visual acuity
24
apps
13
optotype size
12
apps met
12
[sd] error
12
visual
8
acuity testing
8
visual acuity-testing
8
acuity-testing apps
8
apps visual
8

Similar Publications

Purpose: To utilize optical coherence tomography (OCT) and SS-OCT angiography (SS-OCTA) for quantifying morphological changes seen in eyes with recalcitrant neovascular age-related macular degeneration (nAMD) transitioned to intravitreal faricimab injections during the manufacturer's recommended induction phase of treatment.

Methods: Fifty-four treatment-recalcitrant patients (60 eyes) were recruited. OCT and SS-OCTA images were obtained at 0 and 3 months.

View Article and Find Full Text PDF

Background And Objectives: Faricimab, a bispecific antibody targeting VEGF-A and angiopoietin-2, has shown promise in treating neovascular age-related macular degeneration (nAMD). This study evaluates 1-year outcomes of faricimab in treatment-experienced nAMD patients.

Methods: This single-centre retrospective cohort study included patients previously treated for nAMD who switched to faricimab between November 2022 and March 2024.

View Article and Find Full Text PDF

People with amblyopia show deficits in global motion perception, especially at slow speeds. These observers are also known to have unstable fixation when viewing stationary fixation targets, relative to healthy controls. It is possible that poor fixation stability during motion viewing interferes with the fidelity of the input to motion-sensitive neurons in visual cortex.

View Article and Find Full Text PDF

Clinical features, diagnosis, management, and prognosis of circumscribed choroidal hemangioma.

Surv Ophthalmol

January 2025

Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, 100730, China; Key Lab of Ocular Fundus Diseases, Chinese Academy of Medical Sciences, Beijing 100730, China. Electronic address:

Because of its benign nature and rarity, circumscribed choroidal hemangioma (CCH) often receives limited attention, leading to a high rate of misdiagnosis and a lack of standardized treatment protocols. We provide a thorough clarification of the demographics, clinical features, diagnosis, management, and prognosis of CCH. We conducted a systematic search of the PubMed, EMBASE, and Ovid databases up to December, 2023, to identify relevant studies.

View Article and Find Full Text PDF

Background/objectives: The visual acuity (VA) outcomes after the first and second years of anti-vascular endothelial growth factor (anti-VEGF) treatment in patients with diabetic macular oedema (DMO) were evaluated, and the factors associated with treatment success were investigated.

Methods: Using Medisoft electronic medical records (UK), this retrospective cohort study analysed VA outcomes, changes, and determinants in DMO patients at year 1 and year 2 after initial anti-VEGF injection. Descriptive analysis examined baseline demographics and clinical characteristics, while regression models were used to assess associations between these factors and changes in VA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!