With their high degree of specificity and investigator control, in vitro disease models provide a natural complement to in vivo models. Especially in organs such as the brain, where anatomical limitations make in vivo experiments challenging, in vitro models have been increasingly used to mimic disease pathology. However, brain mimetic models may not fully replicate the mechanical environment in vivo, which has been shown to influence a variety of cell behaviors. Specifically, many disease models consider only the linear elastic modulus of brain, which describes the stiffness of a material with the assumption that mechanical behavior is independent of loading rate. Here, we characterized porcine brain tissue using a modified stress relaxation test, and across a panel of viscoelastic models, showed that stiffness depends on loading rate. As such, the linear elastic modulus does not accurately reflect the viscoelastic properties of native brain. Among viscoelastic models, the Maxwell model was selected for further analysis because of its simplicity and excellent curve fit ( = 0.99 ± 0.0006). Thus, mechanical response of native brain and hydrogel mimetic models was analyzed using the Maxwell model and the linear elastic model to evaluate the effects of strain rate, time post mortem, region, tissue type (i.e., bulk brain vs white matter), and in brain mimetic models, hydrogel composition, on observed mechanical properties. In comparing the Maxwell and linear elastic models, linear elastic modulus is consistently lower than the Maxwell elastic modulus across all brain regions. Additionally, the Maxwell model is sensitive to changes in viscosity and small changes in elasticity, demonstrating improved fidelity. These findings demonstrate the insufficiency of linear elastic modulus as a primary mechanical characterization for brain mimetic materials and provide quantitative information toward the future design of materials that more closely mimic mechanical features of brain.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsbiomaterials.8b01390DOI Listing

Publication Analysis

Top Keywords

linear elastic
28
elastic modulus
24
brain mimetic
16
brain
13
viscoelastic models
12
mimetic models
12
maxwell model
12
models
11
disease models
8
modulus brain
8

Similar Publications

This study presents a comprehensive investigation into the intrinsic properties of RNiP (where R = Sm, Eu) filled skutterudite, employing the full-potential linearized augmented plane wave method within density functional theory (DFT) simulations using the WIEN2k framework. Structural, phonon stability, mechanical, electronic, magnetic, transport, thermal, and optical properties are thoroughly explored to provide a holistic understanding of these materials. Initially, the structural stability of SmNiP and EuNiP is rigorously evaluated through ground-state energy calculations obtained from structural optimizations, revealing a preference for a stable ferromagnetic phase over competing antiferromagnetic and non-magnetic phases.

View Article and Find Full Text PDF

Linear elastic iterative method for stability ultimate capacity of equal-leg angle towers.

Sci Rep

December 2024

Key Laboratory of Disaster Prevention and Structural Safety of China Ministry of Education, School of Civil Engineering and Architecture, Guangxi University, Nanning, 530004, China.

An efficient linear elastic iterative method is proposed for the stability ultimate capacity of equal-leg angle towers, using an elastic modulus adjustment strategy in this paper. The angle steel stability generalized yield function (GYF) of AS/NZS4600 is selected, on which a precise homogeneous generalized yield function (HGYF) is developed through dimensionless analysis and regression. Based on the HGYF, the element bearing ratio is proposed as a dynamic threshold for distinguishing high-stress and low-stress elements in equal-leg angle elements.

View Article and Find Full Text PDF

Although the Doppler velocity log is widely applied to measure underwater fluid flow, it requires high power and is inappropriate for measuring low flow velocity. This study proposes a fluid flow sensor that utilizes optical flow sensing. The proposed sensor mimics the neuromast of a fish by attaching a phosphor to two pillar structures (A and B) produced using ethylene propylene diene monomer rubber.

View Article and Find Full Text PDF

This study presents the development of thiol-maleimide/thiol-thiol double self-crosslinking hyaluronic acid-based (HA) hydrogels for use as dermal fillers. Hyaluronic acid with varying degrees of maleimide substitution (10%, 20%, and 30%) was synthesized and characterized, and HA hydrogels were fabricated using two molecular weights of four-arm polyethylene glycol (PEG10K/20K)-thiol as crosslinkers. The six resulting HA hydrogels demonstrated solid-like behavior with distinct physical and rheological properties.

View Article and Find Full Text PDF

Measuring the biomechanical properties of cell-derived fibronectin fibrils.

Biomech Model Mechanobiol

December 2024

Department of Biomedical Engineering, Virginia Commonwealth University, 401 W. Main St., Richmond, VA, 23284, USA.

Embryonic development, wound healing, and organogenesis all require assembly of the extracellular matrix protein fibronectin (FN) into insoluble, viscoelastic fibrils. FN fibrils mediate cell migration, force generation, angiogenic sprouting, and collagen deposition. While the critical role of FN fibrils has long been appreciated, we still have an extremely poor understanding of their mechanical properties and how these mechanical properties facilitate cellular responses.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!