Bioelectrical impedance analysis (BIA) is used to analyze human body composition by applying a small alternating current through the body and measuring the impedance. The smaller the electrode of a BIA device, the larger the impedance measurement error due to the contact resistance between the electrode and human skin. Therefore, most commercial BIA devices utilize electrodes that are large enough (i.e., 4 × 1400 mm) to counteract the contact resistance effect. We propose a novel method of compensating for contact resistance by performing 4-point and 2-point measurements alternately such that body impedance can be accurately estimated even with considerably smaller electrodes (outer electrodes: 68 mm; inner electrodes: 128 mm). Additionally, we report the use of a wrist-wearable BIA device with single-finger contact measurement and clinical test results from 203 participants at Seoul St. Mary's Hospital. The correlation coefficient and standard error of estimate of percentage body fat were 0.899 and 3.76%, respectively, in comparison with dual-energy X-ray absorptiometry. This result exceeds the performance level of the commercial upper-body portable body fat analyzer (Omron HBF-306). With a measurement time of 7 s, this sensor technology is expected to provide a new possibility of a wearable bioelectrical impedance analyzer, toward obesity management.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7806851 | PMC |
http://dx.doi.org/10.1038/s41598-020-79667-3 | DOI Listing |
Gut Liver
January 2025
Department of Radiology, Research Institute of Radiological Science and Center for Clinical Imaging Data Science, Yongin Severance Hospital, Yonsei University College of Medicine, Yongin, Korea.
Background/aims: To evaluate the associations between pediatric fatty liver severity, bioelectrical impedance analysis (BIA), and magnetic resonance imaging parameters, including total psoas muscle surface area (tPMSA) and paraspinal muscle fat (PMF).
Methods: Children and adolescents who underwent BIA and liver magnetic resonance imaging between September 2022 and November 2023 were included. Linear regression analyses identified predictors of liver proton density fat fraction (PDFF) including BIA parameters, tPMSA, and PMF.
Geriatr Gerontol Int
January 2025
Department of Rehabilitation Medicine, Hyogo Medical University, Nishinomiya, Japan.
Aim: One of the parameters that is measurable using bioelectrical impedance is the phase angle (PhA), which is an indicator of skeletal muscle quality. The PhA reflects cellular health and nutritional status and is an important parameter for monitoring recovery after stroke. However, the factors affecting skeletal muscle quality remain unclear.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
Department of Chemical and Biomolecular Engineering, University of California Los Angeles, Los Angeles, California 90095, United States.
To elucidate interfacial dynamics during electrocatalytic reactions, it is crucial to understand the adsorption behavior of organic molecules on catalytic electrodes within the electric double layer (EDL). However, the EDL structure in aqueous environments remains intricate when it comes to the electrochemical amination of acetone, using methylamine as a nitrogen source. Specifically, the interactions of acetone and methylamine with the copper electrode in water remain unclear, posing challenges in the prediction and optimization of reaction outcomes.
View Article and Find Full Text PDFCureus
December 2024
College of Health Care Sciences, Nova Southeastern University, Fort Lauderdale, USA.
The case report explores the effects of testosterone replacement therapy (TRT) on body composition, lean muscle mass, and fat mass, based on the dosage of TRT and exercise intensity in a 40-year-old male. The purpose of this case study was to evaluate the dose-response relationship of TRT and exercise on muscle hypertrophy and fat loss over an eight-month period, using a validated wrist-worn wearable fitness tracker to measure daily physical activity and heart rate (HR)-based exercise intensity. The patient, a trained male with 25 years of consistent exercise experience, reported notable declines in strength and increases in body fat despite maintaining a regular workout routine.
View Article and Find Full Text PDFIn Vivo
December 2024
Department of Gastroenterological Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan.
Background/aim: Body weight loss (BWL) after gastrectomy for gastric cancer (GC) decreases postoperative quality of life and survival in patients with GC. This study aimed to evaluate the effect of oral nutritional supplements composed of high protein on BWL in the early period following gastrectomy.
Patients And Methods: Pre- and postoperative body weight and skeletal muscle mass were measured using bioelectrical impedance analysis in patients undergoing radical gastrectomy for GC and analyzed retrospectively.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!