Background: The aim of this study was to reach a consensus in the classification and standardized reporting for the different types of PCNLs.

Methods: The RAND/UCLA appropriateness methodology was used to reach a consensus. Thirty-two statements were formulated reviewing the literature on guidelines and consensus on PCNLs, and included procedure specific details, outcome measurements and a classification for PCNLs. Experts were invited to two rounds of input, the first enabled independent modifications of the proposed statements and provided the option to add statements. The second round facilitated scoring of all statements. Each statement was discussed in the third round to decide which statements to include. Any suggestion or disagreement was debated and discussed to reach a consensual agreement.

Results: Twenty-five recommendations were identified to provide standardized reporting of procedure and outcomes. Consensual scoring above 80% were strongly agreed upon by the panel. The top treatment related outcomes were size of sheath used (99.1%) and position for PCNL (93.5%). The highest ranked Outcome Measures included definition of postoperative hospital length of stay (94.4%) and estimated blood loss (93.5%).

Conclusions: The consensus statements will be useful to clarify operative technique, in the design of clinical trials and standardized reporting, and presentation of results to compare outcomes of different types of PCNLs.

Download full-text PDF

Source
http://dx.doi.org/10.23736/S2724-6051.20.04107-7DOI Listing

Publication Analysis

Top Keywords

standardized reporting
16
classification standardized
8
consensus statements
8
reach consensus
8
statements
7
consensus
5
reporting
4
reporting percutaneous
4
percutaneous nephrolithotomy
4
nephrolithotomy pcnl
4

Similar Publications

Objective measures of oral PrEP adherence - especially point-of-care (POC) measures that enable real-time assessment, intervention, and feedback - have the potential to improve adherence. Our team previously developed and validated a novel urine-based POC metric of PrEP adherence. In this study, we sought to determine whether this assay is acceptable and feasible among women taking PrEP and PrEP providers in Kenya.

View Article and Find Full Text PDF

Axial spondyloarthritis (ax-SpA) causes pain, fatigue, stiffness, loss of physical function, and poor health status, which can influence sexual activity and enjoyment. To explore whether patients with ax-SpA perceive that their health status effects their sexual activity and to identify predictors of these perceived effects on sexual activity after a 5-year follow-up. Data about demographics, disease, medication, health-related quality of life (HRQOL), and sexual quality of life (SQOL) were collected at the baseline and 5-year follow-up.

View Article and Find Full Text PDF

Background: We performed a systematic review and network meta-analysis (NMA) of individualized patient data (IPD) to inform the development of evidence-informed clinical practice recommendations.

Methods: We searched MEDLINE, Embase, and Cochrane Central in October 2023 to identify RCTs comparing Hartmann's resection (HR), primary resection and anastomosis (PRA), or laparoscopic peritoneal lavage (LPL) among patients with class Ib-IV Hinchey diverticulitis. Outcomes of interest were prioritized by an international, multidisciplinary panel including two patient partners.

View Article and Find Full Text PDF

Introduction: Continued interest in the optimization of recovery in aesthetics has led to the exploration of adjunctive therapies. Hyperbaric oxygen therapy (HBOT) serves as one such therapy that may have an impact in this field. HBOT is hypothesized to improve ischemia, reduce swelling, and minimize secondary hypoxic tissue damage.

View Article and Find Full Text PDF

How to determine hands' vibration perception thresholds - a systematic review.

Behav Res Methods

December 2024

Algoritmi Research Centre, University of Minho, Campus de Azurém, 4800-058, Guimarães, Portugal.

The vibration perception threshold (VPT) is the minimum amplitude required for conscious vibration perception. VPT assessments are essential in medical diagnostics, safety, and human-machine interaction technologies. However, factors like age, health conditions, and external variables affect VPTs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!