Over the past 40 years, the safety and efficacy of percutaneous coronary intervention has dramatically improved by overcoming several challenges. The introduction of drug-eluting stent (DES) in particular was a major breakthrough in interventional cardiology. Compared to bare-metal stents, first-generation DES (G1-DES) has dramatically reduced the rates of in-stent restenosis and subsequent target lesion revascularization. However, major safety concerns surrounding stent thrombosis (ST) emerged with G1-DES in clinical practice as a result of the high incidences of death, myocardial infarction, and repeat revascularization associated with ST. To overcome these limitations, second-generation DES (G2-DES) has been developed with an improved stent platform with thinner strut and biocompatible durable or biodegradable polymers. Indeed, G2-DES, when compared with G1-DES, has improved clinical outcomes by reducing the risk of late thrombotic events while maintaining anti-restenotic efficacy, whereas ST still occurs, even with the use of G2-DES. This review gives an overview of pathophysiology, risk factors, and outcomes of ST after DES implantation. Additionally, we discuss the management and prevention of ST.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s12928-021-00754-xDOI Listing

Publication Analysis

Top Keywords

drug-eluting stent
8
stent thrombosis
8
thrombosis current
4
current future
4
future perspectives
4
perspectives 40 years
4
40 years safety
4
safety efficacy
4
efficacy percutaneous
4
percutaneous coronary
4

Similar Publications

: Acute stent thrombosis (ST) is a rare yet severe complication following percutaneous coronary intervention (PCI). Herein, we investigated the possible association between routinely available coagulation and fibrinolysis markers with early ST. : Within a single-center registry, we investigated the association between the preprocedural platelet count, plasma levels of fibrinogen and D-Dimer, and the incidence of early ST in the first 30 days after PCI.

View Article and Find Full Text PDF

We describe a rare but interesting complication of totally endoscopic robotic mitral valve repair in a patient with severe mitral regurgitation. The mitral valve was repaired robotically by standard techniques, and the intraoperative transesophageal echocardiogram demonstrated no residual mitral regurgitation. However, there was unexpected hypokinesia of the posterior and lateral walls of the left ventricle, with subsequent electrocardiography showing acute ST elevations of the lateral segment.

View Article and Find Full Text PDF

Coronary calcification is a major factor leading to stent under-expansion, and subsequent adverse events. This meta-analysis aimed to evaluate the short and long‑term outcomes of rotational atherectomy (RA), followed by modified balloon (cutting or scoring) (MB) versus plain balloon before drug‑eluting stent implantation for calcified coronary lesions. We searched PubMed, Web of Science (WOS), Scopus, and the Cochrane Library Central Register of Controlled Trials (CENTRAL), from inception until 30 January 2024.

View Article and Find Full Text PDF

Objective: To explore the prognosis and influencing factors of ST-segment elevation myocardial infarction (STEMI) due to late stent thrombosis (LST) and very late stent thrombosis (VLST).

Methods: Patients who underwent percutaneous coronary intervention (PCI) for STEMI caused by LST and VLST at Tianjin Chest Hospital from January 2016 to June 2021 were selected as the study subjects, and long-term follow-up was conducted. The baseline clinical features, laboratory examination indicators, echocardiography results, coronary angiography and intervention treatment characteristics, and antiplatelet treatment status of patients were collected.

View Article and Find Full Text PDF