Value of bone suppression software in chest radiographs for improving image quality and reducing radiation dose.

Eur Radiol

Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, South Korea.

Published: July 2021

Objectives: To compare image quality and radiation dose between dual-energy subtraction (DES)-based bone suppression images (D-BSIs) and software-based bone suppression images (S-BSIs).

Methods: Chest radiographs (CXRs) of forty adult patients were obtained with the two X-ray devices, one with DES and one with bone suppression software. Three image quality metrics (relative mean absolute error (RMAE), peak signal-to-noise ratio (PSNR), and structural similarity index (SSIM)) between original CXR and BSI for each of D-BSI and S-SBI groups were calculated for each bone and soft tissue areas. Two readers rated the visual image quality for original CXR and BSI for each of D-BSI and S-SBI groups. The dose area product (DAP) values were recorded. Paired t test was used to compare the image quality and DAP values between D-BSI and S-BSI groups.

Results: In bone areas, S-BSIs had better SSIM values than D-BSI (94.57 vs. 87.77) but worse RMAE and PSNR values (0.50 vs. 0.20; 20.93 vs. 34.37) (all p < 0.001). In soft tissue areas, S-BSIs had better SSIM values than D-BSI (97.56 vs. 91.42) but similar RMAE and PSNR values (0.29 vs. 0.27; 31.35 vs. 29.87) (all p < 0.001). Both readers gave S-BSIs significantly higher image quality scores than D-BSI (p < 0.001). The mean DAP in software-related images (0.98 dGy·cm) was significantly lower than that in the DES-related images (1.48 dGy·cm) (p < 0.001).

Conclusion: Bone suppression software significantly improved the image quality of bone suppression images with a relatively lower radiation dose, compared with dual-energy subtraction technique.

Key Points: • Bone suppression software preserves structure similarity of soft tissues better than dual-energy subtraction technique in bone suppression images. • Bone suppression software achieves superior image quality for lung lesions than dual-energy subtraction technique in bone suppression images. • Bone suppression software can decrease the radiation dose over the hardware-based image processing technique.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00330-020-07596-wDOI Listing

Publication Analysis

Top Keywords

image quality
20
bone suppression
16
suppression software
8
chest radiographs
8
radiation dose
8
compare image
8
suppression images
8
original cxr
8
cxr bsi
8
bsi d-bsi
8

Similar Publications

Effect of induced astigmatism on vestibulo-ocular reflex.

Clin Exp Optom

January 2025

Department of Optometry, School of Paramedical and Rehabilitation Sciences, Mashhad University of Medical Sciences, Mashhad, Iran.

Clinical Relevance: The vestibular-ocular reflex stabilises the retinal image and maintains balance during head movement. Astigmatism is one of the common refractive errors that can reduce the quality of visual inputs.

Background: The purpose of this study was to investigate the effect of induced astigmatism on the function of the vestibular-ocular reflex.

View Article and Find Full Text PDF

Extracellular vesicles in liquid biopsies: there is hope for oral squamous cell carcinoma.

Extracell Vesicles Circ Nucl Acids

December 2024

Department of Otorhinolaryngology, Head and Neck Surgery, The Chinese University of Hong Kong, Hong Kong Special Administrative Region, Hong Kong 00000, China.

Current approaches to oral cancer diagnosis primarily involve physical examination, tissue biopsy, and advanced computer-aided imaging techniques. However, despite these advances, patient survival rates have not significantly improved. Hence, there is a critical need to develop minimally invasive tools with high sensitivity and specificity to improve patient survival and quality of life.

View Article and Find Full Text PDF

The disease affects the optic nerve and represents the principle reasons of irreversible vision loss, mostly asymptomatic and uncontrolled. Consequently, early and accurate diagnosis is critical to prevent or reduce its effect, however, conventional diagnostic techniques often fail to provide concrete results. In this regard, we present a new approach built on Generative Adversarial Networks (GAN) and MobileNetV2 pretrained architecture for diagnosing glaucoma.

View Article and Find Full Text PDF

Background: Breast cancer patients experience acute radiation dermatitis (ARD) during radiation therapy (RT). This study investigated the prophylactic effect of a newly developed xenogeneic platelet-rich plasma (PRP) lotion on ARD for breast cancer patients.

Methods: This study enrolled patients with ductal carcinoma in situ and early-stage invasive breast cancers after breast-conserving surgery.

View Article and Find Full Text PDF

Objectives: Subclinical myocardial involvement is common in systemic lupus erythematosus (SLE), but differences between new onset and longstanding SLE are not fully elucidated. This study compared myocardial involvement in new onset versus longstanding SLE using cardiovascular magnetic resonance (CMR).

Materials And Methods: We prospectively enrolled 24 drug-naïve new onset SLE patients, 27 longstanding SLE patients, and 20 healthy controls.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!