A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Textile band electrodes as an alternative to spot Ag/AgCl electrodes for calf bioimpedance measurements. | LitMetric

Objective: To evaluate the performance of five different types of textiles as band electrodes for calf bioimpedance measurements in comparison with conventional spot Ag/AgCl electrodes.

Approach: Calf bioimpedance measurements were performed in 10 healthy volunteers with five different textile materials cut into bands and Ag/AgCl spot electrodes as a baseline. Collected bioimpedance data were analyzed in terms of precision, fit error and presence of measurement artifacts. Each textile material was also evaluated for participant comfort.

Main Results: Bioimpedance values for spot electrodes were higher at low frequencies as compared with band electrodes but not at high frequencies. This suggests that spot electrodes have frequency dependent current distributions that adversely impact their use for volume measurements and band electrodes are preferable. The SMP130T-B fabric had the highest precision and the lowest best fit error to the Cole model of the tested textile materials. However, it was the least comfortable textile and most expensive. The Stretch material performed slightly worse than the SMP130T-B fabric, but was half the cost and the most comfortable.

Significance: These results suggest that there are suitable textile materials for use as dry, band electrodes for calf bioimpedance measurements and that these band electrodes enable greater current uniformity. These textiles could be integrated into a compression sock for remote monitoring of diseases such as Congestive Heart Failure.

Download full-text PDF

Source
http://dx.doi.org/10.1088/2057-1976/ab5b02DOI Listing

Publication Analysis

Top Keywords

band electrodes
24
calf bioimpedance
16
bioimpedance measurements
16
electrodes calf
12
textile materials
12
spot electrodes
12
electrodes
10
spot ag/agcl
8
fit error
8
measurements band
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!